跳至主要内容
临床试验/NCT05146037
NCT05146037招募中不适用

INTERvention With Cerebral Embolic Protection in Transcatheter Aortic Valve Implantation (INTERCEPTavi): 'Carbon-Dioxide Flushing Versus Saline Flushing of Transcatheter Aortic Valves: A Single-centre Randomised Controlled Trial'

Imperial College London1 个研究点 分布在 1 个国家目标入组 120 人开始时间: 2021年9月1日最近更新:
适应症

试验速览

阶段
不适用
状态
招募中
入组人数
120
试验地点
1
主要终点
Number of participants suitable for recruitment for larger RCT

研究概览

简要总结

The study aims to evaluate the processes of a pilot single-centre randomised controlled trial (RCT) of carbon-dioxide flushing of transcatheter aortic valves (TAVI-CO2) versus standard saline flushing of valves (TAVI-S) and assess potential neuroprotection through a number of neurological endpoints for planning of a full-sized RCT

详细描述

Aortic stenosis (AS) is one of the most common valve diseases and is increasing worldwide due to an ageing population. Transcatheter Aortic Valve Replacement (TAVI) is a keyhole procedure that can be done through the groin to replace the narrowed aortic valve with a new valve, avoiding the need for cardiac surgery.Improved device design and greater operator experience has improved TAVI outcomes. It has become the standard treatment option in patients who are at high risk for cardiac surgery and is now being used increasingly in lower risk patients.

Cerebrovascular accidents in TAVI patients remain a significant risk with a reported 3 - 5 % risk. Furthermore, these patients have neurovascular injury that is not clinically identifiable. Covert brain injury has been identified to occur in many surgical and cardiovascular catheter-based interventions such as TAVI and can cause vascular brain injury (VBI).

TAVI valves are manufactured in room air conditions and retain air. Studies in TEVAR (Thoracic Endovascular Aortic Repair) stent grafts have shown release of air when they are deployed in the aorta. In vitro testing of TAVI valves has shown release of air when they are deployed.

Carbon-dioxide (CO2) is 1.5 times denser than air and can displace it. It is 25 times more soluble in blood than air and does not lead to bubble formation. Hence CO2 bubble are unlikely to result in significant damage. CO2 has been used in cardiac surgery with beneficial effects. It has shown to reduce peri-procedural cerebral air embolisation and post operative cognitive dysfunction.

This study aims to look at the neuroprotective benefits of flushing TAVI valves with CO2 and saline versus saline only by reducing air embolisation.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Prevention
盲法
Double (Participant, Outcomes Assessor)

盲法说明

Patients and outcome assessors will be blinded to intervention.

入排标准

年龄范围
18 Years 至 100 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • All patients between the ages of 18 and 100 years undergoing transcatheter aortic valve implantation (TAVI) for aortic stenosis under local anaesthetic.

排除标准

  • Patients that lack capacity to provide informed consent
  • Patients that have had a stroke within 12 months
  • Patients aged less than 18 years of age
  • Patients that are pregnant

结局指标

主要结局

Number of participants suitable for recruitment for larger RCT

时间窗: Duration of study, approximately 15 months

Conduct an evaluation of the processes described in this pilot RCT for a full-scale RCT including: 1. Screening, Recruitment and Randomisation 2. Retention in follow-up assessments 3. Study design for a full RCT and identification of important stratification variables 4. Refine sample size calculation for a full RCT

次要结局

  • Incidence of Vascular Brain Injury (VBI) on Diffusion Weighted-Magnetic Resonance Imaging (DW-MRI)(Post TAVI 1-7 days and 6-months post TAVI)

研究者

申办方类型
Other
责任方
Sponsor

研究点 (1)

Loading locations...

相似试验