跳至主要内容
临床试验/NCT02048072
NCT02048072已完成4 期

Funktionelle Evaluation Des Autonomen Nervensystems im Zusammenhang Mit Der Erstmaligen Einnahme Von 0,5mg Fingolimod (Gilenya) Bei Patienten Mit schubförmig Verlaufender Multipler Sklerose

Jochen Vehoff1 个研究点 分布在 1 个国家目标入组 33 人开始时间: 2013年7月最近更新:
适应症
干预措施
相关药物

试验速览

阶段
4 期
状态
已完成
发起方
Jochen Vehoff
入组人数
33
试验地点
1
主要终点
RMSSD Normal Breathing

研究概览

简要总结

This study is designed to primarily evaluate the impact of Gilenya (Fingolimod) on the autonomic nervous system in patients being treated for the first time with Gilenya (Fingolimod). Effects on the cardiovascular system will be studied as well. The study is conducted to answer the question, if, and if yes, what impact the treatment with Gilenya (Fingolimod) has on the autonomic nervous system. To our knowledge little is known about the effects of Gilenya (Fingolimod) on the autonomic nervous system. We do know of rare, but potentially clinically and therapeutically relevant cardiovascular adverse events of Gilenya (Fingolimod). From a scientific point of view the mechanisms by which this is mediated are of interest. Maybe a better understanding of these mechanisms might even be of clinical relevance (e.g. risk stratification).

The impact of Gilenya (Fingolimod) on the autonomic nervous system is quantitavely measured, using a state-of-the-art technique. Non-invasive blood pressure measurement is performed with the Finometer Pro (Finapres Medical Systems, NL) under different paradigms (breathing at rest, deep breath, valsalva maneuver, active standing). In addition the sympathetic skin reaction is performed. The non-invasive blood pressure measurements are done by continuous, plethysmographic blood pressure measurement at the index finger, while the patient is performing the tasks mentioned above. By interpreting the blood pressure curve, heart rate and blood pressure variability are calculated. The sympathetic skin reaction consists of measuring the change of electric conductibility of the skin (palms and soles) after an electric stimulus of a peripheral nerve. These parameters allow to assess the functionality of four important autonomic functional systems (orthostasis, sympathetic adrenergic, sympathetic cholinergic, parasympathetic cholinergic). Normative data has been acquired in our lab.

Our hypothethis is, that there will be a change of heart rate variability at t4,5h compared to baseline (t0) for the parameter "RMSSD" under "normal breathing".

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Basic Science
盲法
None

入排标准

年龄范围
18 Years 至 60 Years(Adult)
性别
All
接受健康志愿者

入选标准

  • indication for treatment with Gilenya according label
  • treatment with Gilenya intended
  • no contraindications for the treatment with Gilanya
  • all safety-aspects have been fullfilled
  • age between 18 and 60 years
  • written consent is given

排除标准

  • relapse during the last 30 days befor randomization
  • steroids within 30 days before randomization
  • heart rhythm disturbance
  • new or currently changed dose (last 4 weeks) of bata-blockers, calcium antagonists, antidepressants or antiarrhythmics
  • diabetes mellitus
  • polyneuropathy
  • missing consent
  • pregnancy
  • lactation period

研究组 & 干预措施

Gilenya

Experimental

Autonomic testing during first dose adminstration of Gilenya.

干预措施: Gilenya (Drug)

结局指标

主要结局

RMSSD Normal Breathing

时间窗: t-4,5 hours

Root Mean Square of the Successive Differences (RMSSD) is one of a few time-domain tools used to assess heart rate variability, the successive differences being neighboring RR or pulse intervals. It is calculated as the square root of the mean of the squares of the successive differences between adjacent RR intervals or pulse intervals. In this study pulse intervals were measured non-invasively during five minutes, while subjects were supine, breathing regularly. Measurements were done at two timepoints t=0 and t=4,5hours. RMSSD was compared between these two timepoints.

次要结局

未报告次要终点

研究者

发起方
Jochen Vehoff
申办方类型
Other
责任方
Sponsor Investigator
主要研究者

Jochen Vehoff

Dr. med. Jochen Vehoff

Cantonal Hospital of St. Gallen

研究点 (1)

Loading locations...

相似试验