Programmed Intermittent Epidural Bolus Versus Continuous Epidural Infusion for Third Trimester Medical Termination of Pregnancy Analgesia : a Randomized Study. (PCEA-IMG)
- Conditions
- Anesthesia, Epidural
- Interventions
- Procedure: Patient Controlled Epidural Analgesia for third trimester termination of preganancy analgesiaDrug: LevobupivacaineDrug: sufentanilDrug: clonidineDevice: epidural catheter
- Registration Number
- NCT02563821
- Lead Sponsor
- University Hospital, Limoges
- Brief Summary
Background : Recently, delivery of local anaesthetics via Programmed Intermittent Epidural Bolus (PIEB) has been shown to improve labour epidural analgesia compared to delivery via Continuous Epidural Infusion (CEI).
Purpose : However, the superiority of PIEB compared to CEI has not been investigated for third trimester voluntary termination of pregnancy.
We hypothesized that PIEB administration would result in a better degree of satisfaction of the patients compared with CEI for third trimester legally induced abortion analgesia.
- Detailed Description
Abstract : The recent technical advances in antenatal diagnosis have led to an increase number of legally induced abortion at the third trimester of pregnancy. Psychological pain is frequently associated to physical pain in these kinds of interventions. So anaesthetists are more and more involved in voluntary termination of pregnancy analgesia.
In France, Patient Controlled Epidural Analgesia (PCEA) with CEI mode is usually used for voluntary termination of pregnancy analgesia. But recent studies have shown that PIEB mode as compared to CEI mode increases maternal satisfaction during labour. This may be attributed to a more extensive spread of epidural solution when delivered as a bolus rather than continuous infusion.
Few trials have been interested in investigating the best mode of PCEA for legally induced abortion analgesia.
This study includes women who undergo voluntary third semester termination of pregnancy. Patients are randomized to PIEB or CEI for pain analgesia. In this randomized, double-blind study, the investigators assess the degree of satisfaction of the patients (primary outcome), the incidence of motor block, total drug consumption and adverse events (secondary outcomes) between the two study groups.
The different values are collected during the intervention on a specific paper for each patient and the degree of satisfaction is reported on this paper just before the patient leaves the birth room (approximatively 2 hours after the expulsion).
Recruitment & Eligibility
- Status
- COMPLETED
- Sex
- Female
- Target Recruitment
- 37
- age ≥ 18 years
- ASA 1 or 2 (healthy women)
- pregnancy at third trimester
- willingness of voluntary interrupt the pregnancy
- women affiliated to french health social system
- written informed consent from every patient
- contraindications to epidural analgesia
- opioids consumption within the last 24 hours
- patient's unwillingness
- inability to comprehend or comply with the procedure
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- PARALLEL
- Arm && Interventions
Group Intervention Description PCEA-DC Patient Controlled Epidural Analgesia for third trimester termination of preganancy analgesia Injection of a 2 mL initial epidural loading dose consisting of a blend (10 mL) of levobupivacaine 20 mg, sufentanil 10 µg to assure the absence of motor block and so exclude intrathecal placement of the epidural catheter. * Injection of the rest of the loading dose (8mL). * In this group the pump is programmed to deliver a continuous infusion at 10 mL /h consisting of levobupivacaine 0,573 mg/mL, sufentanil 0,37 µg/mL, clonidine 1,38 µg/ mL. Additional 5 mL patient-activated boluses will be allowed with a lockout interval of 10 minutes. * If the parturient feels she has inadequate analgesia after having activated the PCEA bolus twice in a thirty minutes period, an additional manual bolus of 6 mL of levobupivacaine 2,5 mg/mL will be administered until the Pain Visual Analog Scale (PVAS) is \< 3/10. PCEA-DC Levobupivacaine Injection of a 2 mL initial epidural loading dose consisting of a blend (10 mL) of levobupivacaine 20 mg, sufentanil 10 µg to assure the absence of motor block and so exclude intrathecal placement of the epidural catheter. * Injection of the rest of the loading dose (8mL). * In this group the pump is programmed to deliver a continuous infusion at 10 mL /h consisting of levobupivacaine 0,573 mg/mL, sufentanil 0,37 µg/mL, clonidine 1,38 µg/ mL. Additional 5 mL patient-activated boluses will be allowed with a lockout interval of 10 minutes. * If the parturient feels she has inadequate analgesia after having activated the PCEA bolus twice in a thirty minutes period, an additional manual bolus of 6 mL of levobupivacaine 2,5 mg/mL will be administered until the Pain Visual Analog Scale (PVAS) is \< 3/10. PCEA-DC sufentanil Injection of a 2 mL initial epidural loading dose consisting of a blend (10 mL) of levobupivacaine 20 mg, sufentanil 10 µg to assure the absence of motor block and so exclude intrathecal placement of the epidural catheter. * Injection of the rest of the loading dose (8mL). * In this group the pump is programmed to deliver a continuous infusion at 10 mL /h consisting of levobupivacaine 0,573 mg/mL, sufentanil 0,37 µg/mL, clonidine 1,38 µg/ mL. Additional 5 mL patient-activated boluses will be allowed with a lockout interval of 10 minutes. * If the parturient feels she has inadequate analgesia after having activated the PCEA bolus twice in a thirty minutes period, an additional manual bolus of 6 mL of levobupivacaine 2,5 mg/mL will be administered until the Pain Visual Analog Scale (PVAS) is \< 3/10. PCEA-DC epidural catheter Injection of a 2 mL initial epidural loading dose consisting of a blend (10 mL) of levobupivacaine 20 mg, sufentanil 10 µg to assure the absence of motor block and so exclude intrathecal placement of the epidural catheter. * Injection of the rest of the loading dose (8mL). * In this group the pump is programmed to deliver a continuous infusion at 10 mL /h consisting of levobupivacaine 0,573 mg/mL, sufentanil 0,37 µg/mL, clonidine 1,38 µg/ mL. Additional 5 mL patient-activated boluses will be allowed with a lockout interval of 10 minutes. * If the parturient feels she has inadequate analgesia after having activated the PCEA bolus twice in a thirty minutes period, an additional manual bolus of 6 mL of levobupivacaine 2,5 mg/mL will be administered until the Pain Visual Analog Scale (PVAS) is \< 3/10. PCEA-BIP Patient Controlled Epidural Analgesia for third trimester termination of preganancy analgesia Injection of a 2 mL initial epidural loading dose consisting of a blend (10 mL) of levobupivacaine 20 mg, sufentanil 10 µg to assure the absence of motor block and so exclude intrathecal placement of the epidural catheter. * Injection of the rest of the loadind dose (8 mL) * In this group the pump is programmed to deliver automated mandatory boluses of 5 mL consisting of levobupivacaine 0,573 mg/mL, sufentanil 0,37 µg/mL, clonidine 1,38 µg/mL every 30 minutes. Additional 5 mL patient-activated boluses will be allowed with a lockout interval of 10 minutes. * If the parturient feels she has inadequate analgesia after having activated the PCEA bolus twice in a thirty minutes period, an additional manual bolus of 6 mL of levobupivacaine 2,5 mg/mL will be administered until the Pain Visual Analog Scale (PVAS) is \< 3/10 (0 = no pain and 10 = insufferable pain). PCEA-BIP epidural catheter Injection of a 2 mL initial epidural loading dose consisting of a blend (10 mL) of levobupivacaine 20 mg, sufentanil 10 µg to assure the absence of motor block and so exclude intrathecal placement of the epidural catheter. * Injection of the rest of the loadind dose (8 mL) * In this group the pump is programmed to deliver automated mandatory boluses of 5 mL consisting of levobupivacaine 0,573 mg/mL, sufentanil 0,37 µg/mL, clonidine 1,38 µg/mL every 30 minutes. Additional 5 mL patient-activated boluses will be allowed with a lockout interval of 10 minutes. * If the parturient feels she has inadequate analgesia after having activated the PCEA bolus twice in a thirty minutes period, an additional manual bolus of 6 mL of levobupivacaine 2,5 mg/mL will be administered until the Pain Visual Analog Scale (PVAS) is \< 3/10 (0 = no pain and 10 = insufferable pain). PCEA-DC clonidine Injection of a 2 mL initial epidural loading dose consisting of a blend (10 mL) of levobupivacaine 20 mg, sufentanil 10 µg to assure the absence of motor block and so exclude intrathecal placement of the epidural catheter. * Injection of the rest of the loading dose (8mL). * In this group the pump is programmed to deliver a continuous infusion at 10 mL /h consisting of levobupivacaine 0,573 mg/mL, sufentanil 0,37 µg/mL, clonidine 1,38 µg/ mL. Additional 5 mL patient-activated boluses will be allowed with a lockout interval of 10 minutes. * If the parturient feels she has inadequate analgesia after having activated the PCEA bolus twice in a thirty minutes period, an additional manual bolus of 6 mL of levobupivacaine 2,5 mg/mL will be administered until the Pain Visual Analog Scale (PVAS) is \< 3/10. PCEA-BIP Levobupivacaine Injection of a 2 mL initial epidural loading dose consisting of a blend (10 mL) of levobupivacaine 20 mg, sufentanil 10 µg to assure the absence of motor block and so exclude intrathecal placement of the epidural catheter. * Injection of the rest of the loadind dose (8 mL) * In this group the pump is programmed to deliver automated mandatory boluses of 5 mL consisting of levobupivacaine 0,573 mg/mL, sufentanil 0,37 µg/mL, clonidine 1,38 µg/mL every 30 minutes. Additional 5 mL patient-activated boluses will be allowed with a lockout interval of 10 minutes. * If the parturient feels she has inadequate analgesia after having activated the PCEA bolus twice in a thirty minutes period, an additional manual bolus of 6 mL of levobupivacaine 2,5 mg/mL will be administered until the Pain Visual Analog Scale (PVAS) is \< 3/10 (0 = no pain and 10 = insufferable pain). PCEA-BIP sufentanil Injection of a 2 mL initial epidural loading dose consisting of a blend (10 mL) of levobupivacaine 20 mg, sufentanil 10 µg to assure the absence of motor block and so exclude intrathecal placement of the epidural catheter. * Injection of the rest of the loadind dose (8 mL) * In this group the pump is programmed to deliver automated mandatory boluses of 5 mL consisting of levobupivacaine 0,573 mg/mL, sufentanil 0,37 µg/mL, clonidine 1,38 µg/mL every 30 minutes. Additional 5 mL patient-activated boluses will be allowed with a lockout interval of 10 minutes. * If the parturient feels she has inadequate analgesia after having activated the PCEA bolus twice in a thirty minutes period, an additional manual bolus of 6 mL of levobupivacaine 2,5 mg/mL will be administered until the Pain Visual Analog Scale (PVAS) is \< 3/10 (0 = no pain and 10 = insufferable pain). PCEA-BIP clonidine Injection of a 2 mL initial epidural loading dose consisting of a blend (10 mL) of levobupivacaine 20 mg, sufentanil 10 µg to assure the absence of motor block and so exclude intrathecal placement of the epidural catheter. * Injection of the rest of the loadind dose (8 mL) * In this group the pump is programmed to deliver automated mandatory boluses of 5 mL consisting of levobupivacaine 0,573 mg/mL, sufentanil 0,37 µg/mL, clonidine 1,38 µg/mL every 30 minutes. Additional 5 mL patient-activated boluses will be allowed with a lockout interval of 10 minutes. * If the parturient feels she has inadequate analgesia after having activated the PCEA bolus twice in a thirty minutes period, an additional manual bolus of 6 mL of levobupivacaine 2,5 mg/mL will be administered until the Pain Visual Analog Scale (PVAS) is \< 3/10 (0 = no pain and 10 = insufferable pain).
- Primary Outcome Measures
Name Time Method satisfaction visual analog scale (SVAS) measurment procedure The degree of satisfaction is assessed using a satisfaction visual analog scale (SVAS) where 0 corresponded to " completely unsatisfied " and 100 to " completely satisfied ".
- Secondary Outcome Measures
Name Time Method Numbers of Adverse events procedure Numbers of Adverse events (Pruritus, nausea / vomitings, episodes of arterial low blood pressure)
Number and intensity of motor block procedure Incidence of motor block determined by number and intensity
Obstetrical informations procedure time of the intervention, doses of oxytocin and prostin used, instrumental delivery
Number of call of the aneshetist for insufficient analgesia procedure Number of call of the aneshetist for insufficient analgesia
Number of doses of complementary manual bolus procedure Number of doses of complementary manual bolus administered
Trial Locations
- Locations (1)
Universiy hospital