MedPath

A New Ultrasonographic Tool to Assess Pulmonary Strain in Patients Under One-lung Ventilation.

Not Applicable
Completed
Conditions
Ventilator-Induced Lung Injury
Mechanical Ventilation Complication
Interventions
Procedure: Lung ultrasonography
Registration Number
NCT03817918
Lead Sponsor
Centre hospitalier de l'Université de Montréal (CHUM)
Brief Summary

Mechanical ventilation is frequently used in the operating room and the intensive care settings. Although essential in many cases, mechanical ventilation can be responsible for ventilator-induced lung injury (VILI). The relationship between mechanical ventilation and VILI has been clearly demonstrated in animals and is highly suspected in humans. The putative mechanism responsible for VILI is excessive pulmonary strain or overdistension. Frequently observed in mechanically ventilated patients, the presence of a severe pre-existing pulmonary disease can increase the risk of overdistension. The development of a tool allowing early detection of pulmonary overdistension would represent a great asset in the prevention of VILI by allowing safer adjustments of mechanical ventilation parameters. Ultrasonographic imaging is a non-radiant, non-invasive technique already available in the intensive care setting. Already used for cardiac strain measurements, ultrasonography is a promising avenue to assess pulmonary strain.

This pilot study will aim to create a small dataset of local pleural strain values assessed at predetermined pulmonary areas using ultrasound imaging in patients undergoing thoracic surgery requiring one-lung ventilation. This dataset will be used to help plan larger scale studies.

Detailed Description

At four different time points during thoracic surgery, images of the pleura of the dependent lung will be made at 2 predetermined areas. The images will be made: after induction (tidal volume of 10 mL/kg), during two-lung ventilation (tidal volume of 10 mL/kg) and during one-lung ventilation (tidal volume of 10 mL/kg and 5 mL/kg). The sites to be studied will be: the 3rd intercostal space at the mid-clavicular line (dependent lung), the 8th intercostal space at the posterior axillary line (dependent lung). Three consecutive respiratory cycles at each site will be recorded for subsequent analysis.

Lung ultrasonography will be performed by the principal investigator and a co-investigator using a Terason (Teratech Corporation, Burlington, MA) device and a 12L5 linear ultrasound probe. For each image, the probe will be oriented perpendicularly to the pleura with the pointer towards the participant's head. A depth of 4 cm will be used and adjusted in order to have the pleural line located between the center and the three-quarts of the screen. The beam's focal zone will be positioned at the level of the pleural line. A 12 MHz frequency will be used.

Using a reference ultrasonographic image, an experienced lung ultrasonographer will segment the pleura. From this image, an algorithm will define a region of interest which will be followed throughout the rest of the images of the video sequence. Thereafter, the algorithm will calculate the various components of pulmonary strain in relation to tidal volume. The principal investigator or a co-investigator will visually validate the speckle-tracking.

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
10
Inclusion Criteria
  • Patients undergoing thoracic surgery in lateral position requiring one-lung ventilation
Exclusion Criteria
  • Obesity (Body Mass Index superior to 30 kg/m2)
  • Emergency surgery
  • Previous thoracic procedure (chest tube, thoracotomy, thoracoscopy)
  • Previous participation to the study
  • Patient refusal

Study & Design

Study Type
INTERVENTIONAL
Study Design
SINGLE_GROUP
Arm && Interventions
GroupInterventionDescription
Determination of local pleural strainLung ultrasonographyThe local pleural strain will be determined over three consecutive respiratory cycles using lung ultrasonography
Primary Outcome Measures
NameTimeMethod
Feasibility of the measurement of local pleural strain using ultrasonographyAt the end of the study on Day 1

Proportion of successfully analyzed lung ultrasonographic clips

Secondary Outcome Measures
NameTimeMethod
Average absolute lateral deformationAt the end of the study on Day 1

Change in percentage from baseline expiratory values

Cumulated range of absolute lateral deformationAt the end of the study on Day 1

Change in percentage from baseline expiratory values

Average absolute lateral shiftAt the end of the study on Day 1

Change in percentage from baseline expiratory values

Cumulated range of absolute lateral shiftAt the end of the study on Day 1

Change in percentage from baseline expiratory values

Average von misesAt the end of the study on Day 1

Change in percentage from baseline expiratory values

Trial Locations

Locations (1)

Centre Hospitalier de l'Université de Montréal (CHUM)

🇨🇦

Montréal, Quebec, Canada

© Copyright 2025. All Rights Reserved by MedPath