MedPath

Ultrasound for Guidewire Detection

Completed
Conditions
Kidney Failure, Chronic
Kidney Failure, Acute
Registration Number
NCT03727581
Lead Sponsor
Wroclaw Medical University
Brief Summary

The aim of the project is to check if there is a possibility for a nephrologist to visualise the guidewire by means of available ultrasound scanners. To evaluate that, the procedure of catheter insertion will be expanded by ultrasound examination of right atrium and inferior vena cava border using substernal view. Such imaging seems to ameliorate the safety of catheter implementation and could be a good alternative for fluoroscopy, eliminating its adverse effects.

Detailed Description

Not available

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
30
Inclusion Criteria
  • Renal failure requiring hemodialysis through a dialysis catheter
  • Capable of giving informed consent
  • Placement of internal jugular vein catheter
Exclusion Criteria
  • Inability to provide informed consent
  • Poor visualisation of inferior vena cava

Study & Design

Study Type
OBSERVATIONAL
Study Design
Not specified
Primary Outcome Measures
NameTimeMethod
Successful guidewire insertion5 minutes

Visualization of guidewire in right atrium-inferior vena cava junction

Successful catheter placement2 hours

Catheter tip in lower part of superior vena cava or right atrium on chest x-ray. Good catheter function.

Secondary Outcome Measures
NameTimeMethod
Complication rate24 hours

Presence of pneumothorax, hematoma, catheter dysfunction

Trial Locations

Locations (1)

Department of Nephrology and Transplantation Medicine

🇵🇱

Wroclaw, Poland

© Copyright 2025. All Rights Reserved by MedPath