Skip to main content
Clinical Trials/NCT06129305
NCT06129305CompletedNot Applicable

Comparison of the Distance of the Erector Spina Muscle From the Skin at Different Thoracal Levels and Different posıtıons Under Ultrasonography

Konya City Hospital1 site in 1 country80 target enrollmentStarted: September 6, 2021Last updated:
Conditions

Trial Snapshot

Phase
Not Applicable
Status
Completed
Sponsor
Enrollment
80
Locations
1
Primary Endpoint
distance of the erector spinae muscle from the skin in millimeters

Study Overview

Brief Summary

In our study, we aimed to calculate the ideal measurement of the distance of the erector spina muscle to the skin and to find the best ultrasonography image at different thoracic levels (T1-T2, T5-T6, T5-T6, T11-T12) and in other positions (lateral-sitting-pron) to improve the quality of the block in patients who will undergo erector spina plan block.

Our primary goal is to determine which thoracic level the erector spinae muscle is closer to the skin and whether the USG screen image is better. Our secondary goal is to find out in which position the erector spinae muscle is closer to the skin and the USG screen image is better.

Detailed Description

1- Abstract Introduction Erector spina plana block can be performed in different positions (sitting-lateral-pron) and at different thoracic levels. In our study, we aimed to calculate the ideal measurement of the distance of the erector spina muscle to the skin and to find the best ultrasonography image at different thoracic levels (T1-T2, T5-T6, T5-T6, T11-T12) and in other positions (lateral-sitting-pron) to improve the quality of the block in patients who will undergo erector spina plan block. Material and Methods A total of 80 patients (40 females and 40 males, ASA I-II) aged 18-65 years were included in the study. The erector spinae muscle was determined at T1-T2, T5-T6, and T11-T12 levels and in lateral, sitting, and prone positions, respectively, with a high frequency 10-15 millihertz linear probe of ultrasound, The distance from the skin to the midline of the ultrasound screen was measured, and the best ultrasound screen image was recorded. Erector spina plan block, distance measurement, different positions, interfascial plan block.

Study Design

Study Type
Observational
Observational Model
Case Only
Time Perspective
Prospective

Eligibility Criteria

Ages
18 Years to 65 Years (Adult, Older Adult)
Sex
All
Accepts Healthy Volunteers
Yes

Inclusion Criteria

  • Patients aged 18-65 years ASA (American Society of Anaesthesiologists) I-II who were to undergo cholecystectomy who were to undergo mastectomy who were to undergo inguinal hernia who were to undergo thoracic surgery

Exclusion Criteria

  • Patients in whom peripheral nerve block was contraindicated uncooperative patients disabled patients emergency cases patients with scoliosis pregnant and breastfeeding women patients with trauma incision scars in the measured area ASA III-IV-V group patients

Outcomes

Primary Outcomes

distance of the erector spinae muscle from the skin in millimeters

Time Frame: two years

Our primary goal is to determine which thoracic level the erector spinae muscle is closer to the skin and whether the USG screen image is better.

Secondary Outcomes

  • clarity of the erector spinae muscle in different positions(two years)

Investigators

Sponsor
Konya City Hospital
Sponsor Class
Other
Responsible Party
Principal Investigator
Principal Investigator

Muhammed Halit Satici

Specialist, Department of Anesthesiology, Konya City Hospital, M.D

Konya City Hospital

Study Sites (1)

Loading locations...

Similar Trials

Erector Spina Muscle Distance From the... | Clinical Trial