跳至主要内容
临床试验/NCT06141668
NCT06141668已完成不适用

Optimal Stimulation Parameters for Spike-ripple Disruption in Patients Undergoing Invasive Monitoring

Massachusetts General Hospital1 个研究点 分布在 1 个国家目标入组 16 人开始时间: 2023年6月13日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
入组人数
16
试验地点
1
主要终点
Spike ripple rate

研究概览

简要总结

Open-loop electrical stimulation has been found to reduce spike activity and seizures, but determining the optimal parameters to achieve these effects requires a brute force trial-and-error approach that relies on subjective physician discretion. We compared the performance of stimulation parameters identified in rodent models to the recommended parameters for neuromodulation used in clinical practice.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Basic Science
盲法
None (Outcomes Assessor)

入排标准

性别
All
接受健康志愿者

入选标准

  • Undergoing intracranial EEG investigation at Massachusetts General Hospital during presurgical epilepsy evaluation.
  • Consented for stimulation experiment.

排除标准

  • Baseline spike ripple rate < 0.5/min.
  • Did not complete 3 hours of stimulation.

研究组 & 干预措施

Within subject multi-frequency stimulation

Experimental

Baseline/no stimulation:

1 Hz stimulation 20 Hz stimulation 40 Hz stimulation 140 Hz stimulation 200 Hz stimulation

干预措施: Neurostimulation (Other)

结局指标

主要结局

Spike ripple rate

时间窗: 1-3 hours

Spike ripple rate (count per minute)

Spike Ripple Rate (Events Per Minute)

时间窗: 3 hours

Spike ripple rate \~ 1 + condition + (1\|subject) This is a within-subject repeated-measures study design analyzed using a generalized linear mixed-effects model. Effect size for each arm (+/- 95% confidence interval) reported below. Treatment response was assessed using the change in spike ripple rate (SR rate) relative to each subject's baseline. For each subject, the treatment response at each stimulation frequency (1 Hz, 20 Hz, 40 Hz, 140 Hz, and 200 Hz) was calculated by subtracting the subject's baseline SR rate from the SR rate measured after stimulation at that frequency. Positive values indicate an increase in SR Rate relative to baseline, whereas negative values indicate a decrease relative to baseline.

次要结局

  • Spike rate(1-3 hours)
  • Spike Rate (Events Per Minute)(3 hours)

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Catherine Chu, MD

Associate Professor Neurology

Massachusetts General Hospital

研究点 (1)

Loading locations...

相似试验