跳至主要内容
临床试验/NCT03218865
NCT03218865已完成不适用

Evaluation of the Dialyzer Vitamin E Coated Effect Inflammatory State of Patients in ESRD and Its Clinical Benefits in Terms of Anemia

Hemotech2 个研究点 分布在 1 个国家目标入组 120 人开始时间: 2013年10月16日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
发起方
Hemotech
入组人数
120
试验地点
2
主要终点
Evolution of the well-known inflammatory marker : High sensibility-CRP

研究概览

简要总结

Evaluation of the effect of a vitamin E coated high flux polysulfone dialyzer on the inflammatory state of patients' end stage renal disease and its clinical benefits in terms of anemia Objectives : To assess the benefits of a vitamin E coated polysulfone membrane on the micro-inflammatory state of chronic dialysis patients Prospective multicenter controlled and randomized study Number of patients : 120 patients (60 patients per group)

详细描述

Coordinator : Pr JP.CRISTOL Montpellier hospital university Rational : The hemodialyzed patients are subject to inflammation due to their pathologies and to the technique. The VIE dialyzer polysulfon coated to vitamin E has been shown to have a favourable action on inflammation and anemia. The investigators want to highlight the influence of vitamine E graft using as controlled dialyzer a similar polysulfon from the same manufacturer without vitamin E.

Medical device : ViE High flux dialyzer -> vitamin E coated polysulfone membrane manufactured by Asahi Kasei Medical, with CE mark and intended for use in hemodialysis for the patient suffering from acute or chronic renal failure Controlled medical device : Leoceed H high flux dialyzer : polysulfone membrane manufactured by Asahi Kasei Medical, with CE mark and intended for use in hemodialysis for patient suffering from acute or chronic renal failure Objectives : To assess the benefits of a vitamin E coated polysulfone membrane on the micro-inflammatory state of chronic dialysis patients Primary end point : Evolution of the well-known inflammatory marker : High sensibility-CRP Secondary end point : Evolution of the following inflammatory markers : IL-6, TNFa, fibrinogen, antibodies anti- LDLox Evolution of Hemoglobin and ERI Evolution of Nutritional parameters : albumin and pre albumin Study design : Prospective multicenter controlled and randomized protocol study Duration : 12 months Number of patients : 120 patients : 60 patients per group 120 patients : 60 patients per group Adult ESRD patient, whatever the origin, treated by HD, thrice a week for about 4 hours and hemo dynamically well balanced Inclusion criteria : Dialyzed patient on synthetic high flux dialyzer for 3 months Patient with a vascular access allowing a blood flow rate ≥ 250 ml/min Patient with micro inflammation, i.e an average CRP between 5 and 20 mg/L on the two last check-up of CRP Patient informed of the study and having signed the inform consent. Exclusion criteria : Underage patient Subjects who are pregnant or planning to become pregnant during the study Patient with an infection influencing the Hb level

Patient with an Iron deficiency showed with :

Transferin saturation < 20 % and/or Ferritin < 100 µg/L, Hemo transfusion in the last two months Patient treated by HF, HDF, biofiltration Patient with infectious risks Subjects who participated in a clinical study involving dialyzers in the last two months

Criteria of exit :

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Adult ESRD patient, whatever the origin, treated by HD, thrice a week for about 4 hours and hemo dynamically well balanced
  • Dialyzed patient on synthetic high flux dialyzer for 3 months
  • Patient with a vascular access allowing a blood flow rate ≥ 250 ml/min
  • Patient with micro inflammation, i.e an average CRP between 5 and 20 mg/L on the two last check-up of CRP
  • Patient informed of the study and having signed the inform consent.

排除标准

  • Underage patient
  • Subjects who are pregnant or planning to become pregnant during the study
  • Patient with an infection influencing the Hb level
  • Patient with an Iron deficiency showed with :
  • Transferin saturation < 20 % and/or Ferritin < 100 µg/L,
  • Patients having received an Hemo transfusion in the last two months
  • Patient treated by HF, HDF, biofiltration
  • Patient with infectious risks
  • Subjects who participated in a clinical study involving dialyzers in the last two months

研究组 & 干预措施

ViE High flux dialyzer

Experimental

vitamin E coated polysulfone membrane manufactured by Asahi Kasei Medical, with CE mark and intended for use in hemodialysis for the patient suffering from acute or chronic renal failure

干预措施: VIE high flux dialyzer (Device)

Leoceed H high flux dialyzer

Active Comparator

polysulfone membrane manufactured by Asahi Kasei Medical, with CE mark and intended for use in hemodialysis for patient suffering from acute or chronic renal failure

干预措施: Leoceed H high flux dialyzer (Device)

结局指标

主要结局

Evolution of the well-known inflammatory marker : High sensibility-CRP

时间窗: one year with a follow-up of three months

Decrease of the CRP marker due the use of vitamin E coated dialyzer

次要结局

  • Inflammatory markers(one year with a follow-up of three months)
  • Anemia parameters(one year with a follow-up of three months)
  • Nutritional Parameters(one year with a follow-up of three months)

研究者

发起方
Hemotech
申办方类型
Industry
责任方
Sponsor

研究点 (2)

Loading locations...

相似试验

Influence of the Vitamine E Coated Dialyzer on... | 临床试验