MedPath

Assessment of Sleep by WHOOP in Ambulatory Subjects

Not Applicable
Completed
Conditions
Sleep Quality
Interventions
Other: No Device
Device: WHOOP Strap 2.0
Registration Number
NCT03692195
Lead Sponsor
University of Arizona
Brief Summary

Polysomnography (PSG) is considered the 'gold standard' for objectively measuring different parameters of sleep, including total sleep time, quality of sleep, and distinguishing between sleep stages. However, PSG is costly, and tends to be burdensome in terms of set-up time and invasiveness during sleep. Wearable sleep-monitoring devices could prove to be a more practical alternative to PSG.

Additionally, while EKG leads are typically what is utilized to measure heart rate (HR) and heart rate variability (HRV) throughout the night in a PSG set-up, every day-use HR monitors are also beneficial for individuals to evaluate their cardiovascular activity during different types of physical activities (including every day activities, exercise, and sleep), as well as their heart's ability to "recover" from a given activity.

The investigators propose to study the effect of the WHOOP Strap 2.0 device on sleep perception and perform a methodological study to validate the accuracy of the the WHOOP Strap 2.0 device when measuring HR accuracy and HRV accuracy, and sleep quality and quantity with respect to PSG in healthy volunteers with no self-reported sleep disorders or debilitating medical conditions.

Detailed Description

Polysomnography (PSG) is still considered the 'gold standard' for measuring sleep parameters, such as total sleep time, sleep efficiency, and sleep stages (6). However, PSG suffers from key limiting factors for routine care applications irrespective of setting (e.g., home, acute setting, and long term setting). Some of the key limitations of PSG are the high cost, arduous application, intrusiveness to sleep, and requirement of sleep lab and dedicated infrastructure. Wearable technologies could provide a viable alternative to PSG. We are proposing to perform a methodological study aimed at validating the accuracy of WHOOP Strap 2.0 to measure sleep quantity and sleep quality in ambulatory subjects. We will measure sleep by both WHOOP Strap 2.0 and PSG in healthy volunteers (age 18 - 45 years) without self-reported sleep disorders or chronic disabling medical conditions.

In ambulatory patients, sleep is usually assessed by the American Academy of Sleep Medicine guidelines which derives from the Rechtschaffen and Kales (R\&K) method with good to excellent inter-observer reliability for assessing sleep in the same population; but the Cohen's K range is still 0.68 to 0.82 and much lower for non rapid eye movement (NREM) sleep stage 1 (N1). To account for such inter- and intra-rater reliability issues with the PSG gold-standard, we will only consider sleep stages that are unequivocally scored as a particular stage (light NREM, slow wave sleep \[SWS\] or REM sleep \[R sleep\]) by two different observers.

Additionally, while there are many devices available to healthy individuals to measure heart rate, there aren't many available that provide a daily heart rate variability statistic. Heart rate variability can be defined as the variation over time of the period between consecutive heart beats. This is due to the balancing regulation effects of the parasympathetic (PNS) and sympathetic (SNS) actions of the autonomic nervous system (ANS). Increased SNS action results in a "fight or flight" response, leading to an accelerated heart rate, while increased PNS activity results in a "rest and digest" response, leading to a decelerated heart rate. The increased variability of heart rate (HR) is an indication of the ANS' control on HR and the heart's ability to respond. WHOOP Strap 2.0 provides users with real-time HR and a daily HRV statistic that is included in other variables calculated measuring daily strain and recovery statistics. We will measure HR and HRV by both WHOOP Strap 2.0 and EKG leads in healthy volunteers (ages 18-45 years) without chronic disabling medical conditions.

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
35
Inclusion Criteria
  • Ability to provide informed consent
  • Willingness to undergo a polysomnography electrode hook-up and wear a WHOOP strap 2.0.
  • Healthy volunteers
Exclusion Criteria
  • Presence of untreated sleep disorder that requires diagnostic testing and treatment (insomnia, obstructive sleep apnea, narcolepsy, restless leg syndrome, REM sleep behavior disorder, or circadian rhythm sleep disorders).
  • Apnea-Hypopnea index greater than or equal to 15 per hour as per AASM guidelines
  • Active substance abuse or alcoholism
  • Pregnancy or lactation
  • Currently taking sedative medications
  • Chronic medical conditions such as hypertension, diabetes mellitus, cardiac disorders, arthritis, or other chronic medical conditions
  • BMI greater than 26

Study & Design

Study Type
INTERVENTIONAL
Study Design
PARALLEL
Arm && Interventions
GroupInterventionDescription
Week WHOOP is not wornNo DeviceParticipants will not wear the WHOOP strap 2.0 either 7 days prior to or 7 days after their sleep study.
Week WHOOP is wornWHOOP Strap 2.0Participants will wear the WHOOP strap 2.0 either 7 days prior to or 7 days after their sleep study.
Primary Outcome Measures
NameTimeMethod
PROMIS Sleep Questionnaire Short FormBaseline, Day 7, and Day 14 (~2 weeks)

An 8-item questionnaire used to assess subjective sleep disturbance in individuals 18 and older. Each questionnaire item addresses an aspect about sleep quality that is rated by the respondent on a 5-point scale (i.e., 1= Not at all \& 5 = Very Much). Change in PROMIS score will be assessed between Baseline, Day 7, and Day 14.

Secondary Outcome Measures
NameTimeMethod
Heart Rate VariabilityThe WHOOP strap 2.0 is worn continuously throughout the duration of the study (~14 days).

Heart Rate Variability is defined as the physiological phenomenon of the variation of time intervals between heart beats. This will be measured by the WHOOP Strap 2.0.

Sleep duration by WHOOP Strap 2.0The WHOOP Strap 2.0 is worn on day 7 of the study. Polysomnography occurs on day 7 of the study.

Sleep duration is defined as the amount of time one spends asleep. This is measured by the WHOOP Strap 2.0 and is compared to Polysomnography, the gold standard for measuring sleep parameters and sleep stages.

Respiratory RateThe WHOOP Strap 2.0 is worn on day 7 of the study. Polysomnography occurs on day 7 of the study.

The WHOOP Strap 2.0 collects respiratory rate. This will be compared to the nasal cannula respiratory rate which is part of the polysomnography montage.

Sleep FragmentationThe WHOOP Strap 2.0 is worn on day 7 of the study. Polysomnography occurs on day 7 of the study.

Sleep fragmentation is defined as interruptions in sleep. This is measured by the WHOOP Strap 2.0 and is compared to Polysomnography, the gold standard for measuring sleep parameters and sleep stages.

Sleep Versus Wake DetectionThe WHOOP Strap 2.0 is worn on day 7 of the study. Polysomnography occurs on day 7 of the study.

The WHOOP Strap 2.0 differentiates between sleep and wake status. This will be compared to polysomnography, which is the gold standard of measuring sleep staging and sleep parameters.

Heart Rate AccuracyThe WHOOP Strap 2.0 is worn on day 7 of the study. Polysomnography occurs on day 7 of the study.

The WHOOP Strap 2.0 collects heart rate. This will be compared to the known gold standard of Electrocardiogram electrode leads as part of the polysomnography montage.

Sleep StagingThe WHOOP Strap 2.0 is worn on day 7 of the study. Polysomnography occurs on day 7 of the study.

The WHOOP Strap 2.0 differentiates between light sleep, slow wave sleep, and REM sleep. This will be compared to polysomnography, which is the gold standard of measuring sleep staging and sleep parameters.

Trial Locations

Locations (1)

Center for Sleep and Circadian Sciences

🇺🇸

Tucson, Arizona, United States