Validity and Reliability of an Activity Monitor in Persons With a Cerebrovascular Accident

University College of Antwerp1 个研究点 分布在 1 个国家目标入组 30 人开始时间: 2009年2月最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
30
试验地点
1
主要终点
Total energy expenditure (kcal)during selected physical activities

研究概览

简要总结

Background:Accelerometry has only recently been introduced in clinical stroke research. However, whether accelerometry is a valid and reliable tool in stroke needs to be established. From literature becomes clear that existing accelerometers show shortages at patients with stroke because of the specific deficits that these patients have.

Purpose: The aim of this study is to investigate the validity and test-retest reliability of the SenseWear Pro armband as an objective measurement of physical activity in chronic stroke patients.

Patients and Methods Subjects: Fifteen patients and fifteen healthy subjects will be included in the study following written informed consent. The following demographic and clinical data were recorded: age, gender, height, length, medication use, self-reported handedness, Edinburgh Handedness Inventory, Rivermead Gross Function, Functional Ambulation Categories, medical and surgical history.

Methods: During one test session the subjects had to carry out an amount of activities according to a standardised protocol existing of lying down, sitting, standing, walking, step exercise and cycling. These activities are presenting activities of daily living.

Measures:Subjects wear on both arms a SenseWear Pro Armband. De data from these measuring devices will be compared with the data retrieved from 2 Yamax pedometers and the ergospirometry device. The outcome measures are: counts, heartbeat, oxygen used, energy expenditure, METabolic equivalent, time lying down.

详细描述

Evaluation of the SenseWear Pro Armband to assess physical activity in individuals with chronic stroke

Background:

Accelerometry has only recently been introduced in clinical stroke research. However, whether accelerometry is a valid and reliable tool in stroke needs to be established. From literature becomes clear that existing accelerometers show shortages at patients with stroke because of the specific deficits that these patients have.

Purpose:

The aim of this study is to investigate the validity and test-retest reliability of the SenseWear Pro armband as an objective measurement of physical activity in chronic stroke patients.

研究设计

研究类型
Observational
观察模型
Case Control
时间视角
Cross Sectional

入排标准

年龄范围
18 Years 至 80 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • 未提供

排除标准

  • 未提供

结局指标

主要结局

Total energy expenditure (kcal)during selected physical activities

时间窗: measurement at 1 time point

次要结局

  • Number of steps(measurement at 1 time point)

研究者

发起方
University College of Antwerp
申办方类型
Other
责任方
Sponsor

研究点 (1)

Loading locations...