Multicenter Comparative Study on the Diagnostic Efficacy of "Ultra-high Sensitivity" Cardiomagnetic Detection and Myocardial Nucleoradiology Scanning for Early Diagnosis of Myocardial Ischemia.
试验速览
- 阶段
- 不适用
- 状态
- 尚未招募
- 发起方
- 入组人数
- 218
- 主要终点
- Evaluation Indicators: Diagnostic concordance between " ultra-high sensitivity" magnetocardiography (MCG) and rest/stress ECT (including exercise and pharmacological stress protocols) for detecting myocardial ischemia.
研究概览
简要总结
Coronary atherosclerotic heart disease (CHD) and Coronary Microvascular Disease (CMVD), as the primary etiologies of myocardial ischemia, have garnered increasing clinical attention due to their high prevalence and severe prognostic implications.
Currently, the primary method for detecting myocardial ischemia is Emission Computed Tomography (ECT). However, it suffers from limitations such as low spatial resolution and radiation exposure risks.magnetocardiography(MCG) is a non-invasive, contactless medical imaging device that maps localized magnetic signals generated by cardiac electrical activity.The magnetocardiography (MCG) system constructs cardiac magnetic field images by recording biomagnetic signals via a multi-channel sensor array positioned above the thoracic region.MCGcan capture the spatial magnetic field changes of ischemic myocardial cells, and carry out early warning, early diagnosis and positioning detection of myocardial ischemia.
This study is a prospective, multicenter, controlled trial. The study will enroll adult patients presenting with myocardial ischemia symptoms suspected of having coronary heart disease (CHD) or coronary microvascular disease (CMVD), who are scheduled to undergo ECT examination.and a domestically manufactured "ultra-high sensitivity" cardiomagnetic detection device will be used to collect cardiac magnetic images. The ECT examination will be completed within one week. A consistency analysis will be conducted between the cardiac magnetic results and the ECT results to evaluate the early diagnostic efficacy of cardiac magnetic detection for myocardial ischemia. Subgroup analyses will also be performed based on resting and stress conditions.
Primary study endpoints:Diagnostic Performance of MCG in Detecting Myocardial Ischemia: Positive Predictive Value, Specificity, and Sensitivity.
Secondary study endpoint:Concordance and Discrepancies Between MCG and ECT in Diagnosing Myocardial Ischemia.
详细描述
- Research Background Magnetocardiography (MCG) is a non-invasive, risk-free, and contactless technology that characterizes the local magnetic field signals generated by the electrical activity of the heart. The magnetic signals from the heart and the electrical signals from the heart are of the same origin. The ionic activity within myocardial cells forms volume currents, and the curve representing the potential difference caused by these currents on the body surface over time is known as the Electrocardiogram (ECG). The spatial magnetic field changes caused by volume currents are referred to as magnetocardiograms. Magnetocardiograms are constructed by recording the magnetic signals of the heart using a multi-channel sensor array placed above the chest, thereby mapping the heart's magnetic field. By analyzing these magnetic maps, abnormal electrical activities of the heart can be detected, including myocardial ischemia, arrhythmias, and myocardial diseases. Traditional ECG detection technology is affected by various conductivities of human tissues and skin, whereas the magnetic signals used in magnetocardiograms can pass through the body with almost no interference. Therefore, magnetocardiography theoretically offers more clinically useful information, with the advantages of being non-invasive, safe, and fast, enabling earlier and more accurate diagnoses of potential heart diseases.Earlier magnetocardiography (MCG) systems were not adopted clinically because of their prohibitive costs and technical challenges.Recently,our country has successfully developed a heart magnetic measurement device based on spin-exchange relaxation-free magnetic measurement technology. This device has successfully completed 64-channel time-sharing heart magnetometry and 32-channel synchronous heart magnetometry.The core component of the heart magnetic detection device is the SERF atomic magnetometer, which uses a novel alkali metal atom operating in the SERF state to achieve extremely weak magnetic measurements. It has advantages such as non-cryogenic operation (traditional magnetometers require cooling with liquid helium), miniaturization, and high spatial resolution.The basic principle is: using high temperature to achieve a higher density of alkali metal vapor in the gas cell, suppressing spin-exchange relaxation, and using polarized detection light that is perpendicular to the pump light entering the gas cell to measure the Larmor precession frequency of spin-polarized atoms in a weak magnetic field, thus accurately reflecting the magnitude of the external magnetic field. The SERF magnetometer has achieved high sensitivity to low-frequency magnetic fields in weak magnetic fields.Therefore, MCG device can ultra-sensitively, non-invasively, and dynamically display human cardiac magnetic functional information, reflecting corresponding electrophysiological activities of the heart. It provides a novel tool for the clinical diagnosis and evaluation of cardiovascular diseases, holding broad application prospects in medicine.
- Research Objectives This study aims to compare the domestically developed "ultra-sensitive" MCG device with ECT, the gold standard for myocardial ischemia detection, to determine whether the domestic "ultra-sensitive" MCG device can accurately identify myocardial ischemia, thereby exploring its clinical application value.
- study design This study is a prospective, multi-center comparative study. 3.1 research contents 3.1.1 Recruit participants and collect data Patients who come to our hospital for treatment with myocardial ischemia symptoms such as chest tightness and chest pain and plan to undergo ECT will be informed by the receiving doctor of the clinical study. Patients who are willing to participate in the study will be further communicated with the patient by the investigator to evaluate and confirm whether they meet the inclusion conditions, and inform that the study will collect clinical diagnosis and treatment information such as basic conditions, medical history, laboratory examinations, as well as study-related precautions, and sign informed consent form.
3.1.2 Preparation before magnetic examination Before undergoing magnetic electrocardiogram, the patient's basic information was asked and checked, the past history, alcohol and tobacco status, and the current medical history (the onset time, inducement, symptom characteristics, duration, etc. of chest pain) were recorded, and the subject's blood pressure, height, and weight were measured.
3.1.3 Magnetocardiography and ECT examination MCG images were collected using a domestic "ultra-high-sensitive" MCG detection device, and ECG examinations were performed 10 minutes before and after. ECT examination was completed within 1 week.
3.1.4 Data Entry The subject's diagnostic results, myocardial damage markers, heart failure indicators, electrocardiogram, echocardiography, coronary CTA/angiography, ECT and other laboratory test results were recorded and entered into EDC.
3.2 Data Analysis The consistency of Magnetocardiographic results and ECT results was analyzed to evaluate the effectiveness of magnetocardiographic testing in early diagnosis of myocardial ischemia.
研究设计
- 研究类型
- Observational
- 观察模型
- Case Only
- 时间视角
- Prospective
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Age ≥18 years
- •Presence of myocardial ischemia-related symptoms (e.g., angina pectoris) with suspected CHD or CMVD, scheduled for ECT examination
- •Signed informed consent form
排除标准
- •Hemodynamic instability (systolic blood pressure <90 mmHg or requiring vasoactive drugs);
- •Cardiac arrhythmias, including ventricular tachycardia, ventricular fibrillation, severe sinus bradycardia and sinus pauses, and second - degree or higher - degree atrioventricular block and other severe arrhythmias;
- •Aortic dissection aneurysm, severe aortic valve stenosis or insufficiency;
- •Elderly or frail patients with neuromuscular or osteoarticular diseases who cannot complete exercise stress ECT; Allergy to drugs used in pharmacologic stress ECT;
- •Patients with severe renal insufficiency with an estimated glomerular 6.filtration rate (eGFR) < 30 ml/min or those undergoing dialysis;
- •Patients with malignant tumors and a life - expectancy of less than1 year;
- •Pregnant or lactating women;
- •Patients unable to undergo MCG examination due to inability to enter the chamber, metallic implant interference, or other conditions deemed unsuitable by researchers.
结局指标
主要结局
Evaluation Indicators: Diagnostic concordance between " ultra-high sensitivity" magnetocardiography (MCG) and rest/stress ECT (including exercise and pharmacological stress protocols) for detecting myocardial ischemia.
时间窗: 2025.7-2026.7
次要结局
未报告次要终点
研究者
Yang Jing
Associate Researcher
Chongqing Emergency Medical Center