Pulmonary Diffusing Capacity During Postural Postural Changes and Acute Exercise
- Conditions
- Clinical Assessments of Pulmonary Diffusing Capacity
- Interventions
- Diagnostic Test: Sitting-to-supineDiagnostic Test: Rest-to-exercise
- Registration Number
- NCT04963504
- Lead Sponsor
- Rigshospitalet, Denmark
- Brief Summary
The combined measurement of the pulmonary diffusing capacity to carbon monoxide (CO) and nitric oxide (NO) (DLCO/NO) has recently been standardised and validated for clinical use. It involves a very short breath-hold time (≤5 seconds), and it may be repeated up to 12 times without affecting measurements, and it is thus ideal for assessing acute changes in pulmonary diffusing capacity and its components during various physiological manoeuvres. The aim of the present study is to compare the test-retest reliability of pulmonary diffusing capacity measurements during postural changes (sitting vs. supine) vs. rest-to-exercise. DLCO/NO will either be measured in the sitting position during rest vs. exercise or in the sitting and supine posture, and this will be repeated within 1-7 days in 20 healthy individuals that will be randomised to one of the two interventions. Statistically,the test-retest relaibility of sitting-to-supine vs. rest-to-exercise changes in DLCO/NO will be compared by parametric methods.
- Detailed Description
Not available
Recruitment & Eligibility
- Status
- COMPLETED
- Sex
- All
- Target Recruitment
- 20
• Regular exercise (1-3 timer per week)
- Any known medical condition that requires regular medication or any known lung condition
- Smoking
- Symptoms of disease within 2 weeks prior to the study
- Abnormal lung function test
- Pregnancy
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- PARALLEL
- Arm && Interventions
Group Intervention Description Sitting-to-supine Sitting-to-supine - Rest-to-exercise Rest-to-exercise -
- Primary Outcome Measures
Name Time Method Between intervention DLNO/DLCO-ratio repeatability coefficient 1 week Test-retest reliability coefficient of rest-to-exercise and supine-to-prone DLNO/DLCO-ratio
Between intervention DLCO repeatability coefficient 1 week Test-retest repeatability coefficient of rest-to-exercise and supine-to-prone DLCO
Between intervention DLNO repeatability coefficient 1 week Test-retest repeatability coefficient of rest-to-exercise and supine-to-prone DLNO
- Secondary Outcome Measures
Name Time Method Between intervention DM repeatability coefficient 1 week Test-retest repeatability coefficient of rest-to-exercise and supine-to-prone DM
Between intervention Vc repeatability coefficient 1 week Test-retest repeatability coefficient of rest-to-exercise and supine-to-prone Vc
Trial Locations
- Locations (1)
Rigshospitalet
🇩🇰Copenhagen, Denmark