Evaluation of the Effectiveness and Safety of AI-Robotics
- Conditions
- Lower Extremity Motor Dysfunction, Spinal Cord Injury
- Interventions
- Device: AiLegs, AiWalker and HKAFO
- Registration Number
- NCT03452059
- Lead Sponsor
- AI-Robotics Technology Co., Ltd
- Brief Summary
Evaluation of the effectiveness and safety of the lower extremity exoskeleton rehabilitation training robot
- Detailed Description
Evaluation of the effectiveness and safety of the lower extremity exoskeleton rehabilitation training robot developed by AI-Robotics Technology Co., Ltd., Beijing for who had lower limb paralysis
Recruitment & Eligibility
- Status
- COMPLETED
- Sex
- All
- Target Recruitment
- 40
- more than18 but less than 60 years old,less than 80 kilos of weight,Gender is not limited
- Confirmed by MR/CT,AIS spinal cord injury grade: A-C level (without walking ability):Damage plane T6-L2
- The muscle tension of the modified Ashworth grade level is less than or equal to 2
- The range of passive motion of the hip and knee joint of the patient is approximately normal in the ankle joint Neutral position
- Upper limb strength and physical strength are sufficient to stabilize the crutches
- Patients are able to understand and actively participate in the training program, agree and sign the informed consent form
- The range of motion of the joints is severely limited and the walking action is limited
- Spinal fractures are not completely healed, the clinical situation is unstable; if not fully confirmed,please go department of orthopedics or other clinical departments for diagnosing
- Skin injury or infection of the lower extremities or the part of wearing robot
- Unstable angina, severe arrhythmia and other heart diseases
- Severe chronic obstructive pulmonary disease
- Unilateral neglect
- Severe cognitive or visual impairment
- Other contraindications or complications that may affect walking training
- Pregnant or lactating women
- The investigators find that patients with poor compliance, unable to complete the study in accordance with the requirements
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- CROSSOVER
- Arm && Interventions
Group Intervention Description HKAFO/RGO AiLegs, AiWalker and HKAFO use hip and knee ankle foot orthosis (HKAFO) assisted walking AiLegs/AiWalker AiLegs, AiWalker and HKAFO use of lower extremity rehabilitation training robot assisted walking (including AiLegs, AiWalker)
- Primary Outcome Measures
Name Time Method Walking efficiency 6 minute average heart increasing rate,measured by times/min
- Secondary Outcome Measures
Name Time Method Cardiovascular response during 6 minute walk test and right before the 6MWT heart rate during and after 6 minute walk test
efficiency of put on or take off the Ailegs/Aiwalker/HKAFO immediately before beginning (pre-) and immediately after finishing (post-) each of 6 minute walk test to measure the time of putting on or taking off the Ailegs/Aiwalker/HKAFO before or after 6 min walk test
RPE questionaire after 6 minute walk test the RPE is recorded after the 6 min walk test
Trial Locations
- Locations (1)
The First Affiliated Hospital of Nanjing Medical University
🇨🇳Nanjing, Jiangsu, China