Infant Chest Compression
- Conditions
- InfantSimulationCardiac Arrest
- Registration Number
- NCT03616938
- Lead Sponsor
- Łukasz Szarpak
- Brief Summary
our aim was to quantitatively compare the quality of chest-compression of the new two thumb chest compression (nTTT) versus the current standard techniques: two finger technique (TFT), two thumb technique (TTHT) as defined by systolic-, diastolic-, mean arterial- and pulse-pressures. Our hypothesis is that nTTT generates higher arterial blood pressures compared to the established TFT and TTHT in an infant manikin model.
- Detailed Description
To simulate the scenario of infant CPR, an ALS Baby trainer manikin (Laerdal Medical, Stavanger, Norway) simulating a 3-month-old infant. The manikin was connected with a fixed-volume arterial system attached to a monitor (Draeger Infinity® Delta; Draegerwerk AG \& Co. KGaA, Luebeck, Germany) via an arterial pressure transducer (Edward Lifesciences: TruWave Disposable Pressure Transducer; Irvine, CA, USA). The arterial circuit composed of a 50-mL bag of normal saline solution (air removed) attached to the manikin chest plate and connected to the transducer with a 20-gauge intravenous catheter and tubing. The manikin was placed on a high adjustable hospital stretcher. The bed was leveled to the iliac crest of each rescuer for standardization. The manikin was previously intubated and ventilation was performed using a resuscitator bag.
Recruitment & Eligibility
- Status
- UNKNOWN
- Sex
- All
- Target Recruitment
- 65
- nurses
- give voluntary consent to participate in the study
- not meet the above criteria
- wrist or low back diseases
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- CROSSOVER
- Primary Outcome Measures
Name Time Method systolic blood pressure (SBP) 1 day The manikin was connected with a fixed-volume arterial system attached to a monitor (Draeger Infinity® Delta; Draegerwerk AG \& Co. KGaA, Luebeck, Germany) via an arterial pressure transducer (Edward Lifesciences: TruWave Disposable Pressure Transducer; Irvine, CA, USA). The arterial circuit composed of a 50-mL bag of normal saline solution (air removed) attached to the manikin chest plate and connected to the transducer with a 20-gauge intravenous catheter and tubing.
- Secondary Outcome Measures
Name Time Method mean arterial pressure (MAP) 1 day The manikin was connected with a fixed-volume arterial system attached to a monitor (Draeger Infinity® Delta; Draegerwerk AG \& Co. KGaA, Luebeck, Germany) via an arterial pressure transducer (Edward Lifesciences: TruWave Disposable Pressure Transducer; Irvine, CA, USA). The arterial circuit composed of a 50-mL bag of normal saline solution (air removed) attached to the manikin chest plate and connected to the transducer with a 20-gauge intravenous catheter and tubing.
diastolic blood pressure (DBP) 1 day The manikin was connected with a fixed-volume arterial system attached to a monitor (Draeger Infinity® Delta; Draegerwerk AG \& Co. KGaA, Luebeck, Germany) via an arterial pressure transducer (Edward Lifesciences: TruWave Disposable Pressure Transducer; Irvine, CA, USA). The arterial circuit composed of a 50-mL bag of normal saline solution (air removed) attached to the manikin chest plate and connected to the transducer with a 20-gauge intravenous catheter and tubing.
Trial Locations
- Locations (1)
Faculty of Medicine, Lazarski University
🇵🇱Warsaw, Masovian, Poland
Faculty of Medicine, Lazarski University🇵🇱Warsaw, Masovian, PolandLukasz SzarpakContact500186225lukasz.szarpak@gmail.com