跳至主要内容
临床试验/NCT05625516
NCT05625516已完成不适用

Bilateral External Torque CT, a Novel Diagnostic Tool for Detection of Syndesmotic Insufficiency

Balgrist University Hospital1 个研究点 分布在 1 个国家目标入组 20 人开始时间: 2023年8月31日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
20
试验地点
1
主要终点
External torque CT

研究概览

简要总结

Study population: the investigator set them sample size to 30 patients.

Primary endpoint (concerning both study questions): is the applied torque measurement in Newton meters (maximum up to 7.5 Nm) up to the pain tolerance limit. For the chronic injuries, a minimum of 5 Nm should be achieved. If this is not possible due to pain, an intra-articular infiltration into the upper ankle joint with 5ml Ropivacaine 2% is performed under sterile conditions.

In addition, fibula translation while exercising the maximum tolerated External Torque CT (maximum up to 7.5 Nm).

Secondary endpoint (1st study question): the comparison to stress fluoroscopy without anesthesia and under anesthesia.

Secondary endpoint (2nd study question): the comparison of patients with and without symptoms. Secondary endpoint in patients who received intra-articular infiltration is the increase in tolerated Newton meters.

详细描述

Isolated injuries to the distal tibiofibular syndesmosis affect approximately 1-17% of all ankle sprains and up to 30% in "high impact" sports. If the injury is missed, chronic syndesmosis instability can lead to prolonged convalescence, pain, and osteoarthritis of the upper ankle. Therefore, early diagnosis is essential for safe and effective treatment.

The diagnosis of syndesmosis insufficiency presents a certain dilemma in foot surgery. Already the differentiation between a simple fibular ligament lesion (low ankle sprain) and a syndesmosis injury (high ankle sprain) is often clinically difficult and only suggests a syndesmosis injury but does not confirm it.

The investigators have developed an external torque device that allows bilateral stressing of the syndesmosis by external rotation. In this case, both lower legs are stabilized by a special knee brace (fibula remains free floating) or by the hip joints, which are end rotated on both sides, while an external rotation force of maximum 7.5Nm (respectively up to the respective pain limit) can be set on both sides by means of torque newton meters. A CT can then be performed under external rotation stress.

In two previous studies (cadaver study and study on healthy subjects) the investigators have seen on the one hand that bilateral external torque CT is able to reliably detect syndesmosis instabilities and on the other hand that in healthy subjects the two ankle joints are comparable.

Based on these results the investigators want to address the following further questions:

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
18 Years 至 75 Years(Adult, Older Adult)
性别
All
接受健康志愿者
否

入选标准

  • •Written informed consent
  • •Patient age of ≥18 yr and ≤75 yr.
  • •Proven acute (<4 weeks) syndesmosis injury (anterior and posterior) on MRI.
  • •Proven chronic (>2 months) syndesmosis injury (anterior and posterior) on MRI with/without surgical stabilization performed.
  • •Healthy opposite side

排除标准

  • •A dependency between patient sponsor and/or project management
  • •Pregnancy (contraindication for CT): in women of childbearing age, a pregnancy test is performed in any case
  • •St.n. previous operation(s) of the affected lower extremity (specifically of the ankle joint).
  • •Severe deformities (osteoarthritis with limited function upper and lower ankle joint, metatarsophalangeal joint).

结局指标

主要结局

External torque CT

时间窗: 24 months

= the applied torque measurement in Newton meters (maximum up to 7.5 Nm) up to the pain tolerance limit. In the chronic injuries, at least 5 Nm should be achieved. If this is not possible due to pain, patients with chronic injuries are infiltrated intra-articularly into the upper ankle joint with 5ml ropivacaine 2% under sterile conditions.

次要结局

未报告次要终点

研究者

发起方
Balgrist University Hospital
申办方类型
Other
责任方
Sponsor

研究点 (1)

Loading locations...