Right Ventricular Lead Placement in a Pacemaker Population: Evaluation of Apical and Alternative Position
- Conditions
- BradycardiaHeart BlockSick Sinus Syndrome
- Interventions
- Procedure: Permanent Cardiac Pacemaker Implantation
- Registration Number
- NCT01647490
- Lead Sponsor
- Ospedale Santa Maria di Loreto Mare
- Brief Summary
This study is a long-term, prospective, and controlled evaluation of the mechanical dyssynchrony induced by right ventricular apical pacing, both in acute (spontaneous and stimulated) and chronic (12 and 24 months); the study also evaluates the benefit of an alternative pacing site through measures of dyssynchrony in acute and chronic.
- Detailed Description
Permanent cardiac pacing plays an important role in cardiac disease management. Since early studies on right ventricular pacing, apex has been the preferred implant site for transvenous endocardial ventricular leads for several reasons: ease of placement, lead stability as well as the design characteristics of the electrode and the fixation system.
It is now also accepted, however, that right ventricle pacing causes a long term deterioration of left ventricular function through complex effects, both at the structural level of the heart wall and at the hemodynamic level in left ventricular load conditions. It is possible that this deterioration is due to a dyssynchrony of contraction induced by pacing at the right ventricular apex. Some authors suggest to pace the right ventricle at alternative sites, i.e. the medium septum (RVS) region, to guarantee a more physiological activation pattern, especially in patients expected to receive high pacing percentages.
However, unequivocal evidences that stimulation of the right ventricular septum is more physiological than the apical pacing are still missing.
Nonetheless, it should be noted that, although a number of studies refer to RV septum as the alternative site for pacing , poor attention has been paid to the unambiguous definition of RV septum region itself. A clear definition and a proper evaluation of the alternative site is therefore important.
Furthermore, from a procedural point of view, it has been demonstrated that acute and chronic electrical performances of the leads positioned at alternative sites, in particular in the region of mid septum, are equivalent to those of the leads positioned at the apical site.
The purpose of this study is to perform a comprehensive assessment of the electrical and mechanical measures obtained by pacing standard RV site (Right ventricular apex, RVA) and alternative RV site (right ventricular septum, RVS). Specifically, the two pacing sites will be compared in terms of electrical dyssynchrony, as assessed by ECG criteria, and in terms of mechanical dyssynchrony, as assessed by echocardiographic criteria.
The primary end point of the study is defined through the evaluation of dyssynchrony measured both in spontaneous rhythm (Vs) and paced rhythm (Vp). The delay between the time to peak systolic velocity of the septum and the LV free wall will be used to define the degree of dyssynchrony; this measurement will be obtained by TDI echocardiographic technique.
Patients will receive any commercially available dual-chamber implantable pacemakers, according to current standard indications. At the end of the implantation and at follow-up visits (12 and 24 months) device programming will follow the clinical practice of the center.
Recruitment & Eligibility
- Status
- UNKNOWN
- Sex
- All
- Target Recruitment
- 408
- indication for a dual chambers cardiac pacemaker device (DDD/DR) according to current guidelines
- Patients who are able to understand and sign an informed written consent
- Patients who will conduct the follow-up in the center for at least 24 months
- Patients age ≥ 18
- Patients with chronic atrial fibrillation or atrial arrhythmias not controlled within 90 days before enrollment
- Pre-existing permanent cardiac pacemaker (PM), defibrillator (ICD) or cardiac resynchronization therapy device (CRT)
- Unplanned or emergency access to the hospital and / or inability to measure the dyssynchrony for the absence of spontaneous rhythm
- Patients participating in other studies that clearly impact the clinical practice of the center or whose protocol would conflict or affect the outcome of this study
- Patient not expected to survive for the duration of the study follow-up due to co-morbid medical condition
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- PARALLEL
- Arm && Interventions
Group Intervention Description Right Ventricular Apex (RVA) Permanent Cardiac Pacemaker Implantation In the RVA group the right ventricular pacing lead will be implanted in the apex region of the right ventricle Right Ventricular Septum (RVS) Permanent Cardiac Pacemaker Implantation In the RVS group the right ventricular pacing lead will be implanted in the septal region (mid septum) of the right ventricle
- Primary Outcome Measures
Name Time Method LV dyssynchrony as measured by Electromechanical delay (EMD 2 weeks The primary outcome measure of this study is to compare the effect of RV Septal (RVS) versus RV Apical (RVA) pacing as measured by echocardiographic/Doppler Index
- Secondary Outcome Measures
Name Time Method Number of heart failure-related hospitalization 24 months To compare the rate of heart failure-related hospitalization between RVS versus RVA pacing
Right ventricular lead and total implant procedure time, fluoroscopy time Implant To compare the procedural time of RVS versus RVA pacing
Change from baseline in R wave in 12-lead ECG 24 months To investigate the relationship between the ECG characteristics at baseline and response to cardiac pacing (as measured by echocardiography as defined in primary outcome measure) at implant and 24 months
Absolute change in LVEF 24 months To evaluate the Left ventricular diastolic and systolic function as measured by Echocardiographic response of absolute change in LVEF
LV dyssynchrony as measured by Electromechanical delay (EMD) 24 months The secondary outcome measure of this study is to compare the effect of RVS versus RVA pacing as measured by echocardiographic/Doppler Index. This extends to 24 months the results obtained with the primary objective at 2 weeks
Symptoms and quality of life scores 24 months To investigate the relationship between the right ventricular lead position and response to cardiac pacing in terms of symptoms and quality of life scores as measured by short form (SF)-12 scores
Trial Locations
- Locations (2)
Azienda Ospedaliero Universitaria "Vittorio Emanuele"
🇮🇹Catania, Italy
Ospedale Santa Maria di Loreto Mare
🇮🇹Naples, Italy