MedPath

Bubble Continuous Positive Airway Pressure (CPAP) With Conventional CPAP for Extubation in Preterm Infants

Not Applicable
Completed
Conditions
Extubation Failure
Interventions
Device: Bubble CPAP
Device: Conventional CPAP
Registration Number
NCT00979433
Lead Sponsor
All India Institute of Medical Sciences, New Delhi
Brief Summary

The objective of this study is to evaluate whether CPAP delivered by bubble CPAP resulted in a greater proportion of infants being successfully extubated when compared with management with ventilator derived CPAP.

Detailed Description

There have been no published randomized trials comparing extubation failure rates of Bubble CPAP with conventional ventilator derived CPAP. Infants of gestation \<32 weeks and of birth weight less than 1500 grams considered by the treating team to be ready for the initial extubation within first week of life were screened for enrolment. All eligible neonates were randomly allocated to bubble CPAP or conventional CPAP.The purpose of this study is to compare whether infants on Bubble CPAP had more chances of successful extubation as compared to infants put on Conventional CPAP.

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
32
Inclusion Criteria
  • Gestation less than 32 weeks
  • Birth weight less than 1500 g
  • Age less than seven days
  • First extubation attempt.
Exclusion Criteria
  • A neonate having any of the following will be excluded from the study-
  • Severe birth asphyxia defined as need for chest compression for more than 30 seconds
  • Suspected congenital neuromuscular disorder
  • Major congenital malformation
  • Grade 3/4 interventricular haemorrhage
  • Hydrops.

Study & Design

Study Type
INTERVENTIONAL
Study Design
PARALLEL
Arm && Interventions
GroupInterventionDescription
Bubble CPAPBubble CPAPAll neonates randomised to bubble CPAP will be put on Bubble CPAP following initial extubation in first week of life.
Conventional CPAPConventional CPAPAll neonates randomly allocated to conventional/ventilator derived CPAP.
Primary Outcome Measures
NameTimeMethod
Extubation failure - defined as need for reintubation and mechanical ventilation for any reason within 72 hours of initial extubationTill 72 hours after extubation
Secondary Outcome Measures
NameTimeMethod
Time to extubation failure in hours.till extubation failure within first 72 hours after extubation

Trial Locations

Locations (1)

All India Institute of Medical Sciences

🇮🇳

New Delhi, Delhi, India

© Copyright 2025. All Rights Reserved by MedPath