Comparative Study Between Pentacam and IOL Master in Measuring Anterior Chamber Depth

Assiut University0 个研究点目标入组 50 人开始时间: 2021年4月1日最近更新:
适应症

试验速览

阶段
不适用
入组人数
50
主要终点
Comparison between values of anterior chamber depth obtained by different devices

研究概览

简要总结

Measuring parameters of anterior segment of the eye accurately is important for diagnosing variety of diseases and for cataract surgeries, glaucoma, refractive surgeries and post-operative follow-up. One of the anterior segment parameters is the anterior chamber depth.

The anterior chamber depth (ACD) measurement provides valuable information in different fields in ophthalmology. Firstly, it is important for the new theoretical biometric formulas used to calculate the power of intraocular lenses (IOLs) .Secondly, phakic IOL implantation requires precise ACD measurement for both surgical planning and IOL power calculation. Thirdly, the ACD is also implicated as a screening risk factor for glaucoma. Additionally, precise ACD measurement is thought to be important to the accurate determination of the optic zone ablation diameter for keratorefractive surgery, as well as for the analysis of postoperative ACD changes.

Different technologies are used in measurement of the anterior chamber depth Such as pentacam and iol maste

详细描述

IOL master :

Optical biometry by the IOL Master was introduced in the United Kingdom in 1999.Its technology is based on laser interfer-ometry with partial coherent light, termed as Partial Coherence Interferometry (PCI).The device uses the principle of PCI to measure the axial length of the eye.While uses a slit-beam photo-graphic technique for ACD measurements For keratometry measurement, six light spots are projected hexagonally on the cornea .The device records the reflection of these images measuring the separation of the opposite pairs of light spots and calculating the corneal radii and toroidal surface curvature. The mean of the taken measurements is considered the corneal power . The displayed K1 and K2 represent the average keratometry values at two major perpendicular meridians .For ACD measurement, the IOL Master directs a slit beam of light 0.7mm wide through the anterior segment at an angle of 38º to the visual axis.The internal software measures the distance between anterior pole of the cornea and the anterior surface of the lens to calculate the ACD . The device takes five ACD measurements in rapid succession; the mean of these readings are taken as the ACD value . For WTW measurement, a digital grey-scale photograph of the anterior surface of the eye is taken after focusing on the iris. The limbus is then detected automatically and the WTW distance is measured

Pentacam :

The Pentacam obtains images of the anterior segment by a rotating Scheimpflug blue Light Emitting Diode (LED) with a wavelength of 475nm. It acquires 50 images in a duration of approximately two seconds. It extracts about 2,760 true elevation points from the obtained images which in turn generates 1 38,000 true elevation points for the both front and back corneal surfacesand from limbus to limbus, including the central part of the cornea . There for, it calculates k-readings of the cornea. The Pentacam HR calculates ACD from the corneal endothelial layer along a line from the apex of the cornea to the anterior surface of the lens . Horizontal WTW was measured by manual placement of callipers on the Scheimpflug image of the horizontal plane of the examined eye; callipers are placed on the corneo-scleral junction then a line is automat-ically drawn between the two points . The length of this line represents the WTW value

研究设计

研究类型
Observational
观察模型
Case Only
时间视角
Cross Sectional

入排标准

年龄范围
18 Years 至 40 Years(Adult)
性别
All
接受健康志愿者

入选标准

  • presenting for glasses
  • asking for refractive surgery

排除标准

  • severe corneal scarring or opacity
  • patients with corneal dystrophy
  • patients with keratoconus
  • patients with previous ocular surgery
  • patients with ocular trauma
  • patients with uveitis

结局指标

主要结局

Comparison between values of anterior chamber depth obtained by different devices

时间窗: One year

Measuring Anterior chamber depth by Pentacam and iol master in eyes with different refractive errors