Oxygen Saturation Measurement With Pulse Oximetry and With Smart Phones and Smart Wearable

Not yet recruiting
Conditions
Oxygen Saturation Measurement
Interventions
Other: Oxgen saturation measurement with validated pulse oximetry
Other: Oxgen saturation measurement with smart electronics
Registration Number
NCT05272943
Lead Sponsor
Brno University Hospital
Brief Summary

Oxgen saturation measurement with the pulse oximetry is considered as a standard of care for respiratory system monitoring. The evaluation of measured oxygen saturation could lead to the clinical decision making in taking care of patient with respiratory failure. Smart electronics (such smart phones, smart watch, and others) are currently equipped with the sensors and applications that allows the peripheral oxygen saturation, however the corelation between the validated measurement (pulse oximetry) and smart electronics measurement is not known at the moment. In case of close correlation and high sensitivity, could be the smart electronics used for oxygenation evaluation of outpatients together with possible early deterioration detection.

Detailed Description

After informed consent from patients and/or legal guardian the oxygen saturation will be measured by calibrated pulse oxymetry (validated for medical use only) and by smart electronics (smart phones and smart wearable) in pediatric patients during the preanesthesia evaluation, under general anesthesia, during the postanesthesia care unit (PACU) stay, and at pediatric intensive care unit (PICU) stay. In one patient, overall 6 measurements in will be performed (3 on right and 3 on left hand).

Recruitment & Eligibility

Status
NOT_YET_RECRUITING
Sex
All
Target Recruitment
120
Inclusion Criteria
  • Informed consent
  • pediatric patients during preanesthesia visit
  • pediatric patients during general anesthesia
  • pediatric patients during PACU stay
  • pediatric patients during PICU stay
Exclusion Criteria
  • outside age limits
  • refused to participate

Study & Design

Study Type
OBSERVATIONAL
Study Design
Not specified
Arm && Interventions
GroupInterventionDescription
General anesthesia measurementOxgen saturation measurement with smart electronicsOxygen saturation will be measured by validated pulse oxymetry and smart electronics in pediatric patients during general anesthesia
PACU measurementOxgen saturation measurement with smart electronicsOxygen saturation will be measured by validated pulse oxymetry and smart electronics in pediatric patients during PACU stay
PICU measurementOxgen saturation measurement with validated pulse oximetryOxygen saturation will be measured by validated pulse oxymetry and smart electronics in pediatric patients during PICU stay
Preanesthesia visit measurementOxgen saturation measurement with validated pulse oximetryOxygen saturation will be measured by validated pulse oxymetry and smart electronics in pediatric patients during preanesthesia visit
Preanesthesia visit measurementOxgen saturation measurement with smart electronicsOxygen saturation will be measured by validated pulse oxymetry and smart electronics in pediatric patients during preanesthesia visit
PICU measurementOxgen saturation measurement with smart electronicsOxygen saturation will be measured by validated pulse oxymetry and smart electronics in pediatric patients during PICU stay
General anesthesia measurementOxgen saturation measurement with validated pulse oximetryOxygen saturation will be measured by validated pulse oxymetry and smart electronics in pediatric patients during general anesthesia
PACU measurementOxgen saturation measurement with validated pulse oximetryOxygen saturation will be measured by validated pulse oxymetry and smart electronics in pediatric patients during PACU stay
Primary Outcome Measures
NameTimeMethod
Pulse oximetry correlationPerioperatively

Pulse oximetry correlation between the validated pulse oximetry and smart electronics

Secondary Outcome Measures
NameTimeMethod
Measurement tolerancePerioperatively

The tolerance of measurement will be evaluated by number of valid measurement attempts