EXecutive Registry: XIENCE V® Everolimus Eluting Coronary Stent System (XIENCE V® EECSS) in the Treatment of the Specific Setting of Patients With Multi-vessel Coronary Artery Disease.
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 400
- 试验地点
- 23
- 主要终点
- Composite endpoint of all Death, MI (Q-wave and non Q-wave), and ischemia-driven Target Vessel Revascularization (TVR) .
研究概览
简要总结
The purpose of this two part study is the assessment of the performance of the XIENCE V® Everolimus Eluting Coronary Stent System (XIENCE V® EECSS) in the treatment of the specific setting of patients with Multi-Vessel Coronary Artery Disease (MVD).
详细描述
This is a clinical evaluation of the XIENCE V® everolimus eluting coronary stent system as a revascularization treatment of patients with multi-vessel coronary artery disease (MVD-CAD).
The sutdy is composed of two parts:
A Randomized Controlled Trial, outlined in a separate posting and the registry portion of this study, which is as follows:
-A prospective controlled registry to analyze the clinical efficacy and safety at mid and long-term follow-up in patients with MVD treated with the XIENCE V® Everolimus Eluting Coronary Stent System (XIENCE V® EECSS).
研究设计
- 研究类型
- Observational
- 观察模型
- Cohort
- 时间视角
- Prospective
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Patient must be at least 18 years of age
- •Patient is able to verbally confirm understanding of risks, benefits and treatment alternatives of receiving the XIENCE V® EECSS and he/she or his/her legally authorized representative provides written informed consent prior to any study related procedure, as approved by the appropriate Medical Ethics Committee of the respective clinical site
- •Patient has been diagnosed a MVD, as documented by coronary angiography, i.e. presenting a severe stenosis (>50%) amenable to PCI in at least 2 major epicardial vessels or their principal bifurcation branches (diagonal or obtuse marginal)
- •Patient must have evidence of myocardial ischemia (e.g., stable or unstable angina, silent ischemia, positive functional study or a reversible change in the electrocardiogram -ECG- consistent with ischemia)
- •Patient must be an acceptable candidate for coronary artery bypass graft (CABG) surgery
- •Patient must agree to undergo all protocol-required follow-up examinations.
- •Angiographic Inclusion Criteria
- •Patients may receive up to 4 planned XIENCE V® EECSS stents, depending on the number of vessels treated and their respective lesion length. When multiple lesions are present in one or more main coronary branches, complete revascularization should be attempted with the implantation of a maximum of 4 planned stents
- •Target lesions must be de novo lesions (no prior stent implant, no prior brachytherapy)
- •Target vessel reference diameter must be between 2.5 mm and 4.0 mm by visual estimate
- •Target lesion < or = 28 mm in length by visual estimation
- •Target lesions must be in a major artery or its principal branches (diagonal or obtuse marginal) with a visually estimated stenosis of > or = 50%
- •Two lesions in a single main coronary artery or its branches do not constitute a MVD situation, therefore this type of patient must not be enrolled
排除标准
- •Patient has had a known diagnosis of acute myocardial infarction (AMI) within 72 hours preceding the index procedure (non-procedural/spontaneous MI, CK-MB > or = to 2 times upper limit of normal) and CK and CK-MB have not returned within normal limits at the time of procedure
- •Patient has current unstable arrhythmias
- •Patient has a known left ventricular ejection fraction (LVEF) <30%
- •Patient has received a heart transplant or any other organ transplant or is on a waiting list for any organ transplant
- •Patient is receiving or scheduled to receive chemotherapy or radiation therapy within 30 days prior to or after the procedure.
- •Patient is receiving immunosuppression therapy or has known immunosuppressive or autoimmune disease (e.g. human immunodeficiency virus, systemic lupus erythematosus etc.)
- •Patient is receiving chronic anticoagulation therapy (e.g. coumadin)
- •Patient has a known hypersensitivity or contraindication to aspirin, paclitaxel, either heparin or bivalirudin, clopidogrel or ticlopidine, everolimus, cobalt, chromium, nickel, tungsten, acrylic and fluoro polymers or contrast sensitivity that cannot be adequately pre-medicated
- •Elective surgery is planned within the first 9 months (+/- 14 days) after the procedure that will require discontinuing either aspirin or clopidogrel
- •Patient has a platelet count <100,000 cells/mm3 or >700,000 cells/mm3, a WBC of <3,000 cells/mm3, or documented or suspected liver disease (including laboratory evidence of hepatitis)
- •Patient has known renal insufficiency (e.g., serum creatinine level of more than 2.5 mg/dl, patient on dialysis)
- •Patient has a history of bleeding diathesis or coagulopathy or will refuse blood transfusions
- •Patient has had a cerebrovascular accident (CVA) or transient ischemic neurological attack (TIA) within the past six months
- •Patient has had a significant GI or urinary bleed within the past six months
- •Patient has other medical illness (e.g., cancer or congestive heart failure) or known history of substance abuse (alcohol, cocaine, heroin etc.) that may cause non-compliance with the protocol, confound the data interpretation or is associated with a limited life expectancy (i.e. less than one year)
- •Patient is already participating in another investigational use device or drug study or has completed the follow-up phase of another study within the last 30 days.
- •Angiographic Exclusion Criteria
- •Target lesion meets any of the following criteria:
- •Left main location
- •Located within an arterial or saphenous vein graft or distal to a diseased arterial or saphenous vein graft (defined as vessel irregularity per angiogram and >20% stenosed lesion by visual estimation)
- •Heavy calcification
- •The patient may need more than 4 planned stents. Bailout stents are allowed but must be of the same type as randomization stent.
结局指标
主要结局
Composite endpoint of all Death, MI (Q-wave and non Q-wave), and ischemia-driven Target Vessel Revascularization (TVR) .
时间窗: 12 months
Composite endpoints are endpoints made up of a range of statistical parameters.
次要结局
- Adjudicated stent thrombosis(at 3 years)
- Revascularizations (TLR/TVR/any revascularization)(3 years)
- Composite endpoint of cardiac death, MI (Q-wave and non Q-wave), and ischemia-driven TLR.(3 years)
- Composite endpoint of all death, MI (Q-wave and non Q-wave), and TVR.(3 years)
- Device success(At time of index procedure)
- Lesion success(At time of index procedure)
- Procedural success defined as: residual in-stent %DS of < 30% using a percutaneous method, without cardiac death, Q-wave MI, non Q-wave MI, or repeat revasc of the target during hospitalization.(At time of index procedure)