跳至主要内容
临床试验/NCT02704949
NCT02704949已完成不适用

Impact of Low Dose Fluoroscopy in Ureteroscopy

University of Sao Paulo General Hospital1 个研究点 分布在 1 个国家目标入组 94 人开始时间: 2015年8月最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
94
试验地点
1
主要终点
radiation exposure

研究概览

简要总结

One of the most effective strategies to decrease radiation exposure during ureteroscopy is to use low dose. However, the quality of the image obtained is inferior to full dose image. The main concern is to maintain the stone free and complication rate despite the inferior quality of image obtained. Our aim was to evaluate if reducing the dose of fluoroscopy to ¼ instead of full dose would impact in a reduction of total radiation exposure despite a possible increase in fluoroscopy time. Also, if this strategy would impact in operation time, stone free rate and complication rate of unilateral semi-rigid ureteroscopy for ureteral stone treatment due too less than optimal fluoroscopy image. All patients over 18 years old diagnosed with ureteral stone from 5 mm to 20 mm in diameter by CT scan were counseled regarding their treatment options. Patients who failed spontaneous passage or medical treatment or chose endourologic treatment were included in this study. Patients with abnormal urinary anatomy such as horseshoe kidney, pelvic kidney or duplex system were excluded from the study.

详细描述

Several studies support an association between increasing cancer risk with increasing exposure to radiation. Typical radiation exposure for a patient submitted to ureteroscopy ranges from 2.5 to 100 mSv. The International Commission on Radiological Protection recommends an annual occupational radiation exposure limit of no more than 50 mSv per year. One of the most effective strategies to decrease radiation exposure during ureteroscopy is to use low dose. However, the quality of the image obtained is inferior to full dose image. The main concern is to maintain the stone free and complication rate despite the inferior quality of image obtained. Our aim was to evaluate if reducing the dose of fluoroscopy to ¼ instead of full dose would impact in a reduction of total radiation exposure despite a possible increase in fluoroscopy time. Also, if this strategy would impact in operation time, stone free rate and complication rate of unilateral semi-rigid ureteroscopy for ureteral stone treatment due too less than optimal fluoroscopy image. All patients over 18 years old diagnosed with ureteral stone from 5 mm to 20 mm in diameter by CT scan were counseled regarding their treatment options. Patients who failed spontaneous passage or medical treatment or chose endourologic treatment were included in this study. Patients with abnormal urinary anatomy such as horseshoe kidney, pelvic kidney or duplex system were excluded from the study.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Prevention
盲法
Quadruple (Participant, Care Provider, Investigator, Outcomes Assessor)

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • ureteral stone from 5 mm to 20 mm in diameter by CT scan

排除标准

  • abnormal urinary anatomy such as horseshoe kidney, pelvic kidney or duplex system

结局指标

主要结局

radiation exposure

时间窗: 2 years

Each group of patients (1/4 dose and full dose) will have assigned one dosimeter to assess the radiation exposure every procedure. The sum of radiation of each group will be compared at the completion of the study (2 years) , because individual radiation exposure is too low to be measured. Radiation exposure will be measured (data stored inside the dosimeter) by dosimeter in mSv units at each procedure and the total sum of radiation will be done at the end of the study (2 years).

次要结局

  • complications(3 months)
  • stone free rate(3 months)

研究者

申办方类型
Other
责任方
Sponsor

研究点 (1)

Loading locations...

相似试验