Skip to main content
Clinical Trials/NCT01164839
NCT01164839
Unknown
Not Applicable

Evaluation of the Factors Affecting the Diagnostic Performance of Coronary CTA With MSCT: a National Multicenter Trial

Capital Medical University1 site in 1 country1,000 target enrollmentJuly 2010

Overview

Phase
Not Applicable
Intervention
Not specified
Conditions
Coronary Artery Disease
Sponsor
Capital Medical University
Enrollment
1000
Locations
1
Last Updated
15 years ago

Overview

Brief Summary

The multicenter study evaluates the diagnostic performance of coronary Computed Tomography Angiogram (CTA) with multi-slice computed tomography (MSCT) in comparison with X-ray coronary angiography and the factors affecting the accuracy of coronary CTA in diagnosing stenosis of coronary arteries. Furthermore, the study tends to establish the standard of image quality and associated factors that may ensure accurate diagnosis of coronary stenosis with coronary CTA.

Detailed Description

Purpose Prospectively evaluating the factors affecting the diagnostic accuracy of coronary CTA with multi-slice CT (including 64-slice CT and dual-source CT) in detecting coronary stenosis, in comparison with quantitative X-ray coronary angiography, to establish the standard of image quality and associated parameters to ensure accurate diagnosis of coronary stenosis with coronary CTA. Detailed Description Over the past few years, the development in CT technology, especially the introduction of 64-slice multi-slice CT (64 MSCT), has permitted the application of coronary CT angiography to detect coronary stenosis in suspected patients with coronary heart diseases. Now, coronary CT angiography has been widely used worldwide. However, the accuracy of coronary CT angiography is always a concern in decision making of proper treatment, especially in determining the existence of significant stenosis in patients with visible coronary arteriosclerosis. Factors affecting the diagnostic accuracy may include spatial resolution, temporal resolution, motion artifacts, banding artifacts, image noise level, calcification, vessel enhancement, operator dependant factors, etc. One or more factors may affect the diagnosis performance in any single case. So it is important to determine the weighting of these factors in stenosis detection and the tolerance of diagnostic accuracy to these adverse factors. Materials and methods 1. Patient Population: About one thousand patients will be recruited over one year from our institution and other hospitals. All patients will undergo coronary CTA for suspected coronary artery disease. Then X-ray coronary angiography will be performed based on the impression on CTA findings from one radiologist (who will not participate the study) and/or clinical suspicion. Cases with both coronary CTA and X-ray coronary angiography in two weeks will be included. Our Institutional Review Board has approved the study. All patients will give informed consent. Patients with acute heart failure, severe arrhythmia and severe renal dysfunction will be excluded from cardiac studies. 2. To identify stenosis, the coronary arteries of all cases were divided into 15 segments for evaluation with coronary CTA and SCA. Coronary stenosis was recorded as percentage narrowing of lumen diameter and degree of stenosis (without stenosis, mild stenosis (≦50%), moderate stenosis (51%\~75%), and severe stenosis (100%)). Experienced radiologists and cardiologists make the assessment independently in a double blind manner. The result of SCA was used as gold standard. 3. The process of coronary CTA examination of each recruited case will be carefully recorded to evaluate the factors that may affect the diagnostic performance of coronary CTA, such as heart rate, contrast injection parameters, delay time, optimal phase for reconstruction, etc. In addition, image quality will be evaluated, including the grading of motion artifact, banding artifact, enhancement, etc. 4. To evaluate operator dependant factors, all the reformations of coronary CTA will be performed by two different operators. The reformed images will also be reviewed by two different observers to evaluate the stenosis, as well as the image quality factors (motion artifacts, banding artifacts, image noise level, calcification burden, vessel enhancement). 5. Statistical analyses will be performed to evaluate the weighting of different factors in affecting the accuracy of coronary CTA.

Registry
clinicaltrials.gov
Start Date
July 2010
End Date
December 2011
Last Updated
15 years ago
Study Type
Observational
Sex
All

Investigators

Sponsor
Capital Medical University

Eligibility Criteria

Inclusion Criteria

  • aged 20 years to 80 years
  • suspected of coronary artery disease
  • capable of cooperation during coronary CT angiography
  • with X-ray coronary angiography within 2 weeks after coronary CTA

Exclusion Criteria

  • refuse or not capable of signing informed consent
  • pregnant or nursing period
  • acute heart failure
  • severe arrhythmia
  • allergic to iodine
  • severe renal failure
  • not capable of breathholding
  • acute myocardial infarction or previous myocardial infarction
  • previous stent implantation
  • change of clinical status between coronary CTA and X-ray coronary angiography

Outcomes

Primary Outcomes

Not specified

Study Sites (1)

Loading locations...

Similar Trials