Non Invasive Measurements of Intracranial Pressure After Aneurysmal Subarachnoid Hemorrhage
试验速览
- 阶段
- 不适用
- 发起方
- 入组人数
- 140
- 试验地点
- 2
- 主要终点
- Presence of an intracranial pressure variation or increase
研究概览
简要总结
In patients at risk of increased intracranial pressure (ICP), ICP measurements require invasive transducers, usually with insertion of a catheter into the cranium, or through a spinal tap. These invasive modalities involve risks and pain and they can be done only in specialized care units, with a high associated cost.
A novel method for detecting changes in ICP has developed recently. The auditory hair cells emit sounds and electric signals in response to sound, which can be easily detected and measured non-invasively with the help of a microphone probe placed in the external ear canal or regular electrodes. Indeed, the cochlear aqueduct connects the cerebrospinal fluid (CSF) spaces to the inner ear in such a way that ICP and inner-ear fluid pressure equalize within seconds.
The evaluation of intracranial hypertension by increased ICP (invasive) is not systematically used after aneurysmal subarachnoid hemorrhage. It is then detected by using routine clinical signs of hydrocephalus or another disorder of cerebrospinal liquid flow, in combination with a standard imaging method (TDM).
The measurement of noninvasive ICP could allow earlier detection of hydrocephalus or another disorder of cerebrospinal liquid flow, and evaluate whether the increase in ICP precedes patient clinical worsening and / or imaging.
详细描述
In patients at risk of increased intracranial pressure (ICP), ICP measurements require invasive transducers, usually with insertion of a catheter into the cranium, or through a spinal tap. These invasive modalities involve risks and pain and they can be done only in specialized care units, with a high associated cost.
A novel method for detecting changes in ICP has developed recently. The auditory hair cells emit sounds and electric signals in response to sound, which can be easily detected and measured non-invasively with the help of a microphone probe placed in the external ear canal or regular electrodes. Indeed, the cochlear aqueduct connects the cerebrospinal fluid (CSF) spaces to the inner ear in such a way that ICP and inner-ear fluid pressure equalize within seconds.
The evaluation of intracranial hypertension by increased ICP (invasive) is not systematically used after aneurysmal subarachnoid hemorrhage. It is then detected by using routine clinical signs of hydrocephalus or another disorder of cerebrospinal liquid flow, in combination with a standard imaging method (TDM).
The measurement of noninvasive ICP could allow earlier detection of hydrocephalus or another disorder of cerebrospinal liquid flow, and evaluate whether the increase in ICP precedes patient clinical worsening and / or imaging.
研究设计
- 研究类型
- Interventional
- 分配方式
- Na
- 干预模型
- Single Group
- 主要目的
- Diagnostic
- 盲法
- None
盲法说明
open
入排标准
- 年龄范围
- 18 Years 至 75 Years(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Patients which had recently (few days) aneurysmal subarachnoid hemorrhage
- •Valid tympanometry test at least for one ear
- •Between 18 and 75 years of age
- •Cochlear response useful at least for an ear which has validate the tympanometry test
- •Written informed consent reviewed and signed by patient
- •Affiliation to a social security scheme
排除标准
- •Invalid tympanometry test for the both ears
- •Collect of cochlear responses impossible for the ear or both ear which validate the tympanometry test
- •Patient refusal after enlightened information
结局指标
主要结局
Presence of an intracranial pressure variation or increase
时间窗: at day 1
Presence of an intracranial pressure variation or increase when physician has diagnosed a clinical or imaging disorder of the cerebrospinal liquid flow with standard diagnose methods (composite outcome measure): clinical signs, TDM and assessment of bifrontal index.
次要结局
- Evolution of ICP before and after the development of disorder of the cerebrospinal liquid flow according to clinical sign and/or TDM.(at day 1)
- Efficiency of the measurement device on repetitive measurement during one year as evaluated by composite outcome measure: clinical signs, TDM.(at day 1)