跳至主要内容
临床试验/NCT01395576
NCT01395576终止2 期

Evaluation of the Genu Neurexa Orthosis in Post Stroke Patients

Hadassah Medical Organization2 个研究点 分布在 1 个国家目标入组 60 人开始时间: 2011年2月最近更新:
适应症

试验速览

阶段
2 期
状态
终止
入组人数
60
试验地点
2
主要终点
Spatiotemporal parameters

研究概览

简要总结

Post stroke patients often suffer from decrease in strength, loss of balance and gait asymmetry. Accordingly, these patients are at high risk for falls and fall-related injury. The presence of spastic or retracted muscles, e.g. the ankle plantar flexors or the quadriceps in combination with hamstrings weakness, causes knee hyperextension, which increases the stance phase duration and makes it difficult to achieve symmetrical gait. Additionally, this gait disorder can be painful as a result of stress to the ligaments and tendons at the posterior aspect of the knee.

The Genu Neurexa orthosis is designed to stabilize the knee, enable balance control and prevent hyperextension. In order to assess the effect of the orthosis on the gait and balance characteristics of stroke patients the investigators will conduct subjective patient's satisfactory questionnaire, complete physical and functional evaluation and gait analysis, as well as dynamic electromyography (EMG) muscle activation patterns. These examinations will be performed 3 times: at the beginning of the trial, after one month and after two months. The trial design is explained in the following paragraph.

The investigators hypothesize that the gait pattern will be improved while using the knee orthosis,as will be expressed by smaller base width and faster walking velocity etc.

详细描述

The 8-week prospective, randomized controlled study design is depicted in Figure 1. The subjects will be randomly divided into two groups: group A (n=30) or group B (n=30). The patients will be randomly assigned to the study groups , using a block sampling method. The gait pattern, symmetry, and balance of each subject will be evaluated according to the tests described below. After the initial evaluation, group A will be fitted with the Genu Neurexa orthosis for the first four weeks of the study. Group B will not receive treatment for the first four weeks of the study. The subjects will be retested after 4 weeks. Then, group A will ambulate without the Genu Neurexa orthosis for the last 4 weeks. Group B will receive the Genu Neurexa orthosis for the last 4 weeks of the study. Both groups will be retested after 8 weeks for the time of enrollment. This design will provide intra-subject and inter-subject comparison.

The evaluation protocol:

The evaluation tools include subjective patient's satisfactory questionnaire, complete physical and functional evaluation and gait analysis (spatio-temporal parameters and paretic knee angle in the sagittal plane), as well as dynamic electromyography (EMG) muscle activation patterns. The evaluation tools are detailed below.

Gait analysis will be performed while subjects walk on a 6m-long walking path. First, video-recorded observational analysis through the coronal and sagittal planes will be performed in order to register the overall walking pattern and compensation mechanisms.

The main outcome measures will be spatiotemporal parameters (stride time, step time, stance duration, swing duration, double support duration, stride length, step length, base width, toe out angle, cadence and velocity) acquired using 4 markers.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Crossover
主要目的
Treatment
盲法
None

入排标准

年龄范围
18 Years 至 65 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patients suffering a first stro(at least 3 months post stroke)
  • Cognitive and cooperative ability to follo instructions.
  • Patients suffering from paresis of leg muscles resulting in knee hyperextension.
  • Ability to walk with or without a walking aid (cane, walker) independently

排除标准

  • Cognitive disorders preventing the subject from understanding the trial protocol, signing a consent form or following the researcher's instructions
  • Skin disease or wounds at the paretic knee
  • Ankle or foot contructure or limited range of motion
  • Orthopaedic injury to the paretic or non-paretic limbs

结局指标

主要结局

Spatiotemporal parameters

时间窗: Up to 3 months

stride time, step time, stance duration, swing duration, double support duration, stride length, step length, base width, toe out angle, cadence and velocity

次要结局

  • Dynamic EMG recordings(Up to 3 months)
  • Sagittal angle of the paretic knee(Up to 3 months)
  • Functional evaluation(Up to 3 months)

研究者

申办方类型
Other
责任方
Sponsor

研究点 (2)

Loading locations...

相似试验