跳至主要内容
临床试验/NCT06195046
NCT06195046撤回不适用

Baroreflex Activation Therapy in Left Ventricular Assist Device Patients Study (BAT-VAD Study)

Medical University of South Carolina0 个研究点目标入组 10 人开始时间: 2025年7月1日最近更新:
适应症

试验速览

阶段
不适用
状态
撤回
入组人数
10
主要终点
6 Minute Hall Walk

研究概览

简要总结

This study will involve LVAD patients who have already received a clinically-indicated BAT (BAROSTIM) device. After recovery from LVAD implant, we will investigate the effects of BAT in a double-blind cross-over study design.

详细描述

Left ventricular assist devices (LVADs) provide a meaningful therapeutic option for patients with end-stage systolic heart failure who cannot receive cardiac transplantation. For these patients, LVADs have been shown to improve mortality, functional capacity, and quality of life [1-3]. With ever-improving technological and procedural advances, the number of LVAD implantations for patients with end-stage cardiomyopathy as bridge to transplant, recovery, or even as destination therapy continues to rise [4]. Despite the short term clinical benefits of LVAD support, studies show that deleterious neurohormonal activation does not abate after LVAD implantation and that left ventricular scarring (or fibrosis) does not regress and may worsen. Similarly, the prevalence of myocardial recovery with LVAD support has been dismally low with <1% of patients recovering to the point where their LVAD can be safely explanted. Given that the majority of patients undergoing LVAD are now doing so with a destination therapy designation, and that the median estimated survival time on LVAD support ranges from 4-6 years, the importance of therapies to maximize chances for myocardial recovery while LVAD supported is evident.

The pathophysiologic reasons underlying the lack of abrogation of sympathetic and neurohormonal signaling with LVAD support, even in the face of adequate hemodynamic support, may center around the non-pulsatile nature of the device. Markham and Levine described sympathetic nerve activity in both pulsatile and nonpuslatile LVAD patients in 2013, demonstrating that patients with nonpulsatile devices had markedly elevated muscle sympathetic nerve activity, though pulsatile LVAD patients and normal controls had similar sympathetic activity. In a sequence of experiments, the authors demonstrated that this was at least partly due to baroreceptor unloading in the nonpulsatile patients. Further studies have demonstrated that plasma norepinephrine levels remain elevated after VAD implant, as do neurohormones in the renin-angiotensin-aldosterone axis. Sympathetic neurohormone levels have been shown to correlate with clinical response to LVAD therapy (defined by significant improvement in quality of life determined by the KCCQ), with reduced B-adrenergic receptor kinase-1 and DHPG levels differentiating those with better clinical response. Further, pathologic studies pre- and post-LVAD have demonstrated an acceleration of deleterious myocardial fibrosis during LVAD support, potentially driven by sympathetic and/or RAAS signaling pathways.

As demonstrated in preclinical studies and the clinical BeAT-HF trial, autonomic modulation with baroreflex activation therapy (BAT) with the BAROSTIM NEO system reduced sympathetic signaling, leading to increased NT-proBNP, 6-minute hall walk distance (6MHW), and improved quality of life in patients with chronic systolic heart failure.

However, the role of BAT in the unique physiologic LVAD-supported state has not be characterized. Given the concerns that LVAD support by augment sympathetic and thereby RAAS signaling, and that BAT may abrogate those deleterious pathways, we propose to study the clinical and neurohormonal effects of BAT in LVAD supported patients.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Crossover
主要目的
Supportive Care
盲法
Double (Participant, Investigator)

盲法说明

patient and Investigator will not know whether the subject has BAT turned on or off during each of the 3 month follow-up intervals

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Age > 18 years
  • LVAD patient > 3 months post implant
  • Existing BAT device

排除标准

  • Presence of cardiogenic shock, respiratory failure, hypotension or unstable heart failure
  • Bradycardia (resting HR <60 beats/minute)
  • Presence of suspected pump thrombosis at the time of enrollment
  • Presence of any significant ventricular arrhythmias at the time of enrollment

结局指标

主要结局

6 Minute Hall Walk

时间窗: 3 months

change in distance walked during 6 Minute Hall Walk

次要结局

  • Change in serum renin(3 months, 6 months)
  • Minnesota Living with Heart Failure Questionnaire(3 months, 6 months)
  • Change in LVAD system monitor reported flow(3 months, 6 months)
  • Cardiac 123-mIBG scan(3 months, 6 months)
  • Change in left ventricular size on transthoracic echocardiogram(3 months, 6 months)
  • Change in mitral valve regurgitation severity on transthoracic echocardiogram(3 months, 6 months)
  • Change in Serum catecholamines(3 months, 6 months)
  • Change in serum aldosterone(3 months, 6 months)
  • Change in aortic valve opening frequency on transthoracic echocardiogram(3 months, 6 months)
  • Change in right ventricular size on transthoracic echocardiogram(3 months, 6 months)
  • Change in Serum norepinephrine(3 months, 6 months)
  • Change in serum BNP(3 months, 6 months)
  • Change in serum angiotensin(3 months, 6 months)

研究者

申办方类型
Other
责任方
Sponsor

相似试验