跳至主要内容
临床试验/NCT03859232
NCT03859232撤回不适用

Effectiveness of Cotton vs. Waterproof Cast Padding After Application of Hip Spica: A Randomized Controlled Study

Baylor College of Medicine1 个研究点 分布在 1 个国家开始时间: 2018年3月29日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
撤回
试验地点
1
主要终点
Effectiveness as a measure of change in ratings at different time points

研究概览

简要总结

This study aims to: 1) investigate the effectiveness of waterproof spica cast using Delta-Dry® Pantaloon and cast padding (BSN medical, USA) versus standard gortex pantaloon with cotton cast padding in maintaining the femur fracture and developmental dysplasia of the hip reduction after application of hip spica; 2) evaluate the overall quality ratings of both cast paddings from the perspectives of the patient and the clinicians; and 3) determine the cost difference between the both cast paddings.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Other
盲法
Single (Participant)

入排标准

年龄范围
0 Years 至 5 Years(Child)
性别
All
接受健康志愿者
否

入选标准

  • •Paediatric patients (<6 years old) diagnosed with developmental dysplasia of the hip or femur fracture who present to Texas Children's Hospital and plan to be treated with a spica cast.

排除标准

  • •Patients with thigh diameter more than 13.4 inches will be excluded because of the size limitation of the Delta-Dry Pantaloon
  • •Patients with femur fracture who present for treatment more than 2 weeks from the date of injury, comminuted fracture, non-displaced fracture, or with other surgical comorbidity

研究组 & 干预措施

Delta Dry® Pantaloon Group

Experimental

干预措施: Delta Dry® Waterproof Pantaloon (Other)

Cotton Padding Group

Active Comparator

干预措施: Cotton Padding (Other)

结局指标

主要结局

Effectiveness as a measure of change in ratings at different time points

时间窗: Baseline, 2, 6 and 12 weeks post-application

The primary outcome (effectiveness) will be measured based on the change in ratings to the following variables/factors using a 10 point likert scale (1 being very poor and 10 being excellent): Comfort, Ability for the cast to dry if it became wet, Cast odor, Cast durability, Protection from skin irritation, Ease of care in the cast, Ease of Application, Padding Aesthetics, Application Time, Skin Condition, Lack of Maceration / Excoriation, Cast Odor, Padding Condition, and Ease of Removal. These will be collected at baseline, 2, 6 and 12 weeks post-application.

次要结局

  • Quality(Baseline, 2, 6 and 12 weeks post-application)

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Scott Rosenfeld

Associate Professor of Orthopaedic Surgery

Baylor College of Medicine

研究点 (1)

Loading locations...

相似试验