NCT01405287已完成2 期

A Prospective Randomized Study to Compare Vascular Healing After Deployment of the Abluminal Sirolimus Coated Bio-Engineered (Combo) Stent Versus the Everolimus Eluting Stent in Patients With Acute Coronary Syndrome by Means of OCT

OrbusNeich12 个研究点 分布在 5 个国家目标入组 60 人开始时间: 2011年10月1日最近更新:
适应症
干预措施

试验速览

阶段
2 期
状态
已完成
发起方
OrbusNeich
入组人数
60
试验地点
12
主要终点
Percentage of uncovered stent struts per stent at follow-up (OCT)

研究概览

简要总结

OBJECTIVE It is the objective of the REMEDEE OCT study to assess vascular healing after deployment of the Abluminal Sirolimus Coated Bio-Engineered Stent (Combo Bio-Engineered Sirolimus Eluting Stent) in patients with Acute Coronary Syndrome (ACS) with single de novo native coronary artery lesions ranging in diameter from ≥2.5 mm to ≤3.5 mm and ≤ 20 mm in length.

STUDY DESIGN The REMEDEE OCT study is a prospective, multicenter, randomized study designed to enroll 60 patients with ACS who will be randomized 1:1 to be treated with the Combo stent versus the commercially available everolimus eluting stent (Xience V or Promus). Patients will receive Optical Coherence Tomography (OCT) and Quatitative Coronary Angiography (QCA) follow-up imaging at 60 days post procedure. Clinical follow-up is scheduled at 30, 60, 180, 360 and 540 days. Furthermore, QCA and OCT will also be performed at baseline in all participants of the study.

详细描述

BACKGROUND The implantation of bare-metal stents (BMS) has significantly reduced clinical and angiographic restenosis compared to balloon angioplasty alone after PCI due to eliminating elastic recoil and reducing arterial remodeling. However, in-stent restenosis still occurred frequently after BMS implantation in 20% to 40% of patients due to neointimal proliferation. The development, clinical validation and widespread use of drug-eluting stents (DES) have revolutionized the treatment of patients with coronary artery disease. Large-scale, prospective, multicenter double-blind randomized trials have provided strong evidence that drug-eluting stents significantly reduce angiographic restenosis and enhance event-free survival compared with BMS after implantation in native coronary arteries (3-6).However, despite an improved efficacy in the prevention of restenosis and target vessel failure safety concerns have been raised for DES, focusing on a small but clinically important increase in stent thrombosis occurring greater than one year after the index procedure.

In patients receiving drug-eluting stents, the acute coronary syndrome has been identified as one of the major risk factors of stent thrombosis (10). Therefore, concerns about the long-term outcome and safety after drug-eluting stent implantation due to late stent thrombosis and late stent malapposition have been raised.

Stent thrombosis, in particular late stent thrombosis, has been related to an impaired stent healing, most of all to a reduced endothelial repair, i.e. reduced stent strut coverage, after implantation of drug-eluting stents. This has resulted in the recommendation of a prolonged 12-month double antiplatelet therapy with aspirin and clopidogrel after drug-eluting stent implantation, however, how long double antiplatelet therapy is needed is unknown at present. These observations have resulted in an intense search for alternative strategies to promote stent healing and endothelial repair, rather than to inhibit the endothelialisation of the stent, that is common to the substances used to prevent neointima formation.

Notably, endothelial repair can be substantially stimulated by CD34+ endothelial progenitor cells. The Combo stent is therefore covered with a CD34+ antibody to attract endothelial progenitor cells to promote endothelial and stent healing, and on the abluminal side releases sirolimus to prevent neointima formation and restenosis. Several preclinical studies in the porcine coronary artery model have shown, that endothelialisation and stent healing are accelerated in the Combo stent. The present study has therefore been designed to compare stent healing of the Combo stent with the everolimus-eluting stent by optical coherence tomography analysis (optical frequency domain imaging; OFDI), a high resolution intracoronary imaging technique allowing accurate evaluation of stent coverage and healing, in patients with an acute coronary syndrome. Previous studies have indicated, that coronary stent healing after DES implantation is particularly impaired in patients with ACS, and therefore this patient population is in a particular need of improved "pro-healing" stent concepts with a high efficacy.

RATIONALE An important limitation of stents eluting only growth-inhibiting substances is, that also the desirable endothelial cell growth over the stent struts is prevented, that is thought to represent a major cause of "late-stent-thrombosis". The rationale for the design of the "combo-stent" is therefore to combine a growth inhibiting substance with abluminal release with an endothelial progenitor cell attracting design to promote endothelial repair. In the pre-clinical studies, the "Combo Stent" demonstrated significantly lower neointimal hyperplasia, while also showing improved endothelial coverage relative to other commercially available DES. There was also a noticeably lower presence of inflammation and foreign body reaction.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
Single (Participant)

入排标准

年龄范围
18 Years 至 80 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • age ≥18 and ≤ 80 years
  • ST or Non-ST-segment elevation MI (assumed to be a type 1)
  • Acceptable CABG candidate
  • Patient willing to comply with specified follow-up
  • Patient or legally authorized representative has been informed of the nature of the study, agrees to its provisions and has been provided written informed consent
  • Single de novo or non-stented restenotic lesion in a native coronary artery
  • Patients with 2-vessel coronary disease, may have undergone successful treatment (<20% diameter stenosis by visual estimate) of the non-target vessel with approved devices up to and including the index procedure but must be prior to the index target vessel treatment. Any non-target vessel or lesion intended to be treated during the index procedure or follow-up, cannot be an unprotected left main, ostial lesion, chronic total occlusion, heavily calcified, bifurcation, vein grafts, be anything requiring atherectomy, thrombectomy, or pre-treatment with anything other than balloon angioplasty;
  • Target lesion (maximum length is 20 mm by visual estimate) to be covered by a single stent of max 23 mm (stent coverage incl at least 3 mm of healthy vessel is recommended). The lesion length to be measured after pre-dilation
  • Reference vessel diameter ≥2.5 to ≤ 3.5 mm by visual estimate
  • The vessel diameter should be measured after pre-dilation procedure and after intra-coronary nitroglycerin if spasm is suspected
  • Target lesion ≥50% and <100% stenosed by visual estimate

排除标准

  • Pregnant or nursing patients and those who plan pregnancy in the period up to 1 year following index procedure. Female patients of childbearing potential must have a negative pregnancy test done within 7 days prior to the index procedure per site standard test
  • Impaired renal function or on dialysis
  • Platelet count <100,000 cells/mm3 or >700,000 cells/mm3 or a WBC<3,000 cells/mm3
  • Patient has a history of bleeding diathesis or coagulopathy or patients in whom anti-platelet and/or anticoagulant therapy is contraindicated
  • Patient requires low molecular weight heparin (LMWH) treatment postprocedure or has received a dose of LMWH ≤8 hours prior to index procedure
  • Patient has received any organ transplant or is on a waiting list for any organ transplant;
  • Patient has other medical illness or known history of substance abuse that may cause non-compliance with the protocol, confound the data interpretation or is associated with a limited life expectancy (<1 year)
  • Patient has a known hypersensitivity or contraindication to aspirin, heparin/bivalirudin, clopidogrel/ticlopidine, prasugrel, stainless steel alloy, sirolimus and/or contrast sensitivity that cannot be adequately pre-medicated
  • Patient has previously received murine therapeutic antibodies and exhibited sensitization through the production of Human Anti-Murine Antibodies
  • Patient presents with cardiogenic shock
  • Patient has extensive peripheral vascular disease that precludes safe 6 French sheath insertion;
  • Any significant medical condition which in the Investigator's opinion may interfere with the patient's optimal participation in the study
  • Currently participating in another investigational drug or device study or patient in inclusion in another investigational drug or device study during follow-up
  • Unprotected left main coronary artery disease with ≥50% stenosis
  • Ostial target lesion(s)
  • Totally occluded target vessel (TIMI flow 0)
  • Calcified target lesion(s) which cannot be successfully predilated
  • Target lesion has excessive tortuosity unsuitable for stent delivery and deployment;
  • Target lesion involving bifurcation with a side branch ≥2.0 mm in diameter (either stenosis of both main vessel and major side branch or stenosis of just major side branch) that would require intervention of diseased side branch
  • A significant (>50%) stenosis proximal or distal to the target lesion that cannot be covered by same single stent
  • Diffuse distal disease to target lesion with impaired runoff
  • Pre-treatment with devices other than balloon angioplasty
  • Prior stent within 10 mm of target lesion
  • Intervention (PCI or bypass) of any lesion in the target vessel performed within the previous 6 months
  • Intervention (PCI or bypass) of another lesion in a non-target vessel performed within 30 days prior to the index
  • Planned intervention of another lesion (target vessel or non-target vessel) within 30 days.

研究组 & 干预措施

Combo Stent

Experimental

PTCA with Combo Stent

干预措施: PTCA with stent placement (Device)

Everolimus Eluting Stent (EES)

Active Comparator

PTCA with DES (Everolimus Eluting Stent: Xience V or Promus)

干预措施: PTCA with stent placement (Device)

结局指标

主要结局

Percentage of uncovered stent struts per stent at follow-up (OCT)

时间窗: 60 days

次要结局

  • Secondary Clinical Endpoints: components of MACE: MI(30, 60, 180, 360, 540 days)
  • Secondary OCT Endpoints (7/12)(60 days)
  • Secondary OCT Endpoints (12/12)(60 days)
  • Secondary Clinical Endpoints: Stent thrombosis(30, 60, 180, 360, 540 days)
  • Secondary OCT Endpoints (10/12)(60 days)
  • Secondary Clinical Endpoint: Major Adverse Cardiac Events (MACE)(30, 60, 180, 360, 540 days)
  • Secondary Clinical Endpoint: components of MACE: cardiac death(30, 60, 180, 360, 540 days)
  • Secondary OCT Endpoints (11/12)(60 days)
  • Secondary OCT Endpoints (2/12)(60 days)
  • Secondary OCT Endpoints (3/12)(60 days)
  • Secondary OCT Endpoints (4/12)(60 days)
  • Secondary OCT Endpoints (5/12)(60 days)
  • Secondary OCT Endpoints (9/12)(60 days)
  • Secondary Clinical Endpoints: components of MACE: CABG or re-PTCA of target lesion(30, 60, 180, 360, 540 days)
  • Secondary OCT Endpoints (1/12)(60 days)
  • Secondary OCT Endpoints (6/12)(60 days)
  • Secondary OCT Endpoints (8/12)(60 days)

研究者

发起方
OrbusNeich
申办方类型
Industry
责任方
Sponsor

研究点 (12)

Loading locations...

相似试验

Study of Vascular Healing With the Combo Stent... | 临床试验