跳至主要内容
临床试验/NCT02226211
NCT02226211Unknown3 期

Ambu® Aura-iTM Laryngeal Mask Versus Air-QTM Intubating Laryngeal Airway as Conduits for Tracheal Intubation in Adults. A Randomized Comparative Clinical Trial

Cairo University1 个研究点 分布在 1 个国家目标入组 50 人开始时间: 2014年6月最近更新:
适应症

试验速览

阶段
3 期
入组人数
50
试验地点
1
主要终点
duration of fiberoptic guided insertion of the ETT through the device

研究概览

简要总结

Supraglottic airway devices (SGA) become a routine part of the daily anesthesia practice. they can be used as primary airway devices or as conduits for endoracheal intubation and they become an integral part in the recent guidelines for managing difficult airway.

Air-Q ILA has been used successfully as 1ry airway and also as a conduits for endotracheal intubation.

The Ambu® Aura-i TM laryngeal mask is a new disposable SGA claimed to have special advantage over the competitors but not will studied as a conduit for endoracheal intubation.

This study is designed to compare the performance of Ambu®Aura-i™ laryngeal mask with the air-Q ILA as conduits for fiberoptic-guided tracheal intubation in adult population.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
盲法
Single (Outcomes Assessor)

入排标准

年龄范围
18 Years 至 60 Years(Adult)
性别
All
接受健康志愿者

入选标准

  • patients aged from 18-60 years old, ASA I and II and scheduled for elective surgery under general anesthesia

排除标准

  • history of cardiopulmonary disease, gastro-esophageal reflux disease, abnormal airway anatomy, body mass index > 30 kg.m-2, surgical procedures including head and neck or performed in position other than supine or lithotomy

结局指标

主要结局

duration of fiberoptic guided insertion of the ETT through the device

时间窗: duration of induction of general anesthesia, an expected average of 20 minutes. and it is the time span between disconnection of the breathing circuit from the device till reconnection to the ETT and appearance of 1st capnogram wave.

次要结局

  • duration of device insertion(duration of induction of general anesthesia, an expected average of 20 minutes and it is the time span between removal of the face mask till device insertion and the chest rise seen after two consecutive positive pressure manual breaths.)
  • Time of device removal(duration of induction of general anesthesia, an expected average of 20 minutes, and it is the time span between disconnection of the breathing circuit from ETT and reconnection to ETT after device removal with appearance of the 1st capnogram wave.)
  • complication during the procedure(average of 20 minutes after induction of general anesthesia, it is the time from removal of face mask, till removal of the device and appearance of the first wave on the capnogram)
  • number of insertion attempts(duration of induction of general anesthesia, an expected average of 20 minutes and it is the time span from removal of face mask till complete insertion or failed third insertion trial of the device)
  • vital sign in form of mean arterial blood pressure, heart rate and oxygen saturation(average of 20 minutes, and it is the time from time of induction of general anesthesia til completion of endotracheal intubation)

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Abeer Ahmed, MD

lecturer

Cairo University

研究点 (1)

Loading locations...

相似试验

Ambu Aura-i Laryngeal Mask Versus Air-Q Intubating... | 临床试验