Skip to main content
Clinical Trials/NCT03994250
NCT03994250
Completed
Not Applicable

Kinematic Alignment Compared to Mechanical Alignment Techniques for Total Knee Replacement Surgery (KARMA)

Robert Jones and Agnes Hunt Orthopaedic and District NHS Trust1 site in 1 country15 target enrollmentFebruary 10, 2017

Overview

Phase
Not Applicable
Intervention
Not specified
Conditions
Osteo Arthritis Knee
Sponsor
Robert Jones and Agnes Hunt Orthopaedic and District NHS Trust
Enrollment
15
Locations
1
Primary Endpoint
Oxford Knee Score
Status
Completed
Last Updated
5 years ago

Overview

Brief Summary

Total knee replacement (TKR) is a bony and soft-tissue procedure and much attention has been given to the alignment of the components, which is relatively easy to quantify. Recently, substantial healthcare resources have been devoted to the development and use of computer navigation and patient-specific instrumentation systems that achieve neutral mechanical alignment. However the conventional assumption that mechanically aligned TKR leads to the best implant survival has been brought into doubt. Although mechanically aligned TKR improves function, 20 % of patients remain dissatisfied according to reports from Canada, England and Wales.

In an attempt to improve patient satisfaction recent developments have included the individualization of component alignment with the goal of achieving pre-arthritic alignment through restoration of the axes of rotation, a technique called kinematic alignment (KA). The outcomes of kinematic alignment have been assessed in case series but so far only one randomised controlled trial (RCT) [Digital Object Identifier (DOI)10.1302/0301-620X.96B7.32812 Published 1 July 2014] undertaken in the USA has compared the clinical results of kinematic alignment using patient-specific instruments with the traditional technique of mechanical alignment, demonstrating a substantial benefit in postoperative patient pain relief and function. Therefore, for direct comparison between kinematic aligned and mechanically aligned surgical techniques for total knee replacement, the investigators would like to undertake a pilot study prior to a larger RCT and recruit a cohort of 15 patients undergoing kinematical aligned TKR. The investigators will use the same device as was used in a previous mechanically aligned study undertaken at our hospital (REC ref: 12/NE/0293 Attune, DePuy, Warsaw IN, in 35 patients based on the same eligibility criteria who will act as controls), which will allow the opportunity to estimate the standard deviation in the control arm in preparation for the larger RCT.

Detailed Description

In order to be able to undertake a randomized controlled trial (RCT) comparing the efficacy of kinematic alignment versus conventional mechanical alignment for total knee replacement a robust assessment of the expected standard deviation of the primary outcome measure (Oxford Knee Score \[OKS\]) in both arms of the proposed RCT must be undertaken, hence this pilot study. To determine whether there are improved postoperative outcomes in the investigative arm using the following patient reported outcomes: Knee Implant Performance (PKIP - pre and post surgical), Knee Injury and Osteoarthritis Outcome Score (KOOS), Knee Society Score (KSS), Knee Noise and Front of Knee Pain Score and Quality of Life score EQ-5D which will be completed at baseline(pre-operatively) and post-operatively at 6 weeks (normal clinical follow up), 1 year (normal clinical follow up) and 2 years. In addition, x-rays of the knee (AP, lateral \& skyline) will be taken at the same time. These outcomes are identical to the data collected in the previous mechanically aligned study which will be used as the control arm. Much attention has been given to the alignment of the components in total knee replacement (TKR) and this is relatively easy to quantify, particularly in the coronal plane. However, due to the development and use of computer navigation and patient-specific instrumentation systems that achieve neutral mechanical alignment, the conventional assumption that mechanically aligned TKR leads to the best implant survival has been brought into doubt. Although mechanically aligned TKR improves function, 20 % of patients remain dissatisfied according to reports from Canada, England and Wales. The relationship between in-range and varus (turned inward toward the mid line of the body to an abnormal degree) and valgus (turned outward) outlier categories of the limb and implant survival of a primary total knee replacement is weak at 15 years. Leaving a limb, knee, or tibial component within a natural range of varus does not reduce implant survival at 3, 5, 7, and 10 years. With the development of individualization of component alignment and the goal of achieving pre-arthritic alignment through restoration of the axes of rotation, the kinematic alignment technique has shown in case series and one RCT in the USA a substantial benefit in postoperative patient pain relief and function. For direct comparison between kinematic aligned and mechanically aligned surgical techniques for total knee replacement, the investigators will conduct a pilot study prior to a larger RCT and recruit a cohort of 15 patients undergoing kinematic aligned TKR. The investigators will use the same device as was used in a previous mechanically aligned study undertaken at our hospital (REC ref: 12/NE/0293 Attune, DePuy, Warsaw IN, in 35 patients based on the same eligibility criteria who will act as controls), which will allow the opportunity to estimate the standard deviation in the control arm in preparation for the larger RCT.

Registry
clinicaltrials.gov
Start Date
February 10, 2017
End Date
January 1, 2021
Last Updated
5 years ago
Study Type
Interventional
Study Design
Sequential
Sex
All

Investigators

Sponsor
Robert Jones and Agnes Hunt Orthopaedic and District NHS Trust
Responsible Party
Sponsor

Eligibility Criteria

Inclusion Criteria

  • Male or female between the age of 22 and 80 years inclusive
  • Diagnosis of non-inflammatory degenerative joint disease
  • Suitable candidate for cemented primary total knee arthroplasty
  • Voluntary, informed consent to participate in the study
  • Subject is not currently bedridden
  • Able to understand (in the opinion of the clinical investigator) the clinical investigation and co-operate with clinical investigations
  • Subject is able to comfortably speak, read and understand questions

Exclusion Criteria

  • Females who are pregnant or lactating
  • Contralateral knee already enrolled in the study
  • Previous partial knee replacement (unicompartmental, bicompartmental or patellofemoral joint replacement), patellectomy, high tibial osteotomy or primary TKA in affected knee
  • Contralateral amputation
  • Currently experiencing radicular pain from the spine
  • Participated in a study with an investigational product in the last 3 months
  • Currently involved in any personal injury litigation, medical-legal or workers compensation claims
  • Known drug or alcohol abuser or a psychological disorder that could affect their ability to complete patient reported questionnaires
  • Diagnosed with fibromyalgia that is currently being treated with prescription medication
  • Significant neurological or musculoskeletal disorders or disease that may adversely affect gait or weight bearing (e.g. muscular dystrophy, multiple sclerosis, Charcot disease)

Outcomes

Primary Outcomes

Oxford Knee Score

Time Frame: up to 2 years post surgery

Questionnaire, highest score 48 indicates good mobility and no knee pain

Oxford Knee Score measuring current mobility and knee pain

Time Frame: Up to 2 weeks prior to surgery

Questionnaire, highest score 48 indicates good mobility and no knee pain

Secondary Outcomes

  • Knee Noise and Front of Knee Pain(Up to 2 years post surgery)
  • Knee Injury and Osteoarthritis Outcome Score (KOOS)(up to 2 years post surgery)
  • Knee Society Score (KSS)(Up to 2 years post surgery)
  • Quality of Life Score (EQ-5D)(Up to 2 years post surgery)
  • Patient Knee Implant Performance(Up to 2 years post surgery)

Study Sites (1)

Loading locations...

Similar Trials