Adapta Clinical Study to Evaluate the Overall System Safety and Clinical Performance of the Adapta Pacing System

Medtronic Cardiac Rhythm and Heart Failure7 个研究点 分布在 6 个国家目标入组 120 人开始时间: 2005年5月1日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
120
试验地点
7
主要终点
Freedom from adverse device effects

研究概览

简要总结

Pacemakers are implantable devices that pace (electrically stimulate) the heart. Some pacemakers have special programs to treat irregular atrial rhythms(top chambers of the heart beat too fast or too slow). Advances in pacemaker technology in recent years include features that automatically adapt to patient conditions without intervention from the clinician. Adapta (Model #ADDR01) is a new pacemaker that is designed to provide further automaticity advances by including the managed ventricular pacing (MVP) feature designed to promote intrinsic conduction (natural flow of electricity in the heart) by reducing unnecessary ventricular (lower chamber of the heart) pacing (electrical impulses). Adapta also contains a feature called TherapyGuide that is designed to allow the user to select certain conditions for each subject and receive a list of suggested pacemaker parameter value changes based on those conditions. The purpose of this study is to evaluate the overall system safety and clinical performance of the Adapta pacing system.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Single Group
主要目的
Prevention
盲法
None

入排标准

年龄范围
0 Years 至 —(Child, Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Subjects who have a Class I or II indication for implantation of a dual chamber pacemaker according to ACC/AHA/NASPE guidelines
  • Subjects who have signed a Medical Ethics Committee (MEC) approved Informed Consent Form

排除标准

  • Subjects with a mechanical tricuspid valve
  • Subjects with a life expectancy less than two years
  • Subjects with a Class III indication for permanent pacing
  • Subjects with lead integrity problems, unless leads are being replaced

结局指标

主要结局

Freedom from adverse device effects

次要结局

  • To assess right ventricular (lower right chamber of the heart) pacing
  • To summarize all adverse events reported in the study
  • To describe Adapta system performance as observed during Holter recording, save-to disk-files and technical observations
  • To evaluate the user acceptance of TherapyGuide via questionnaire data