Skip to main content
Clinical Trials/NCT02008032
NCT02008032
Withdrawn
Not Applicable

Comparison of Stationary Breast Tomosynthesis and 2-D Digital Mammography in Patients With Breast Augmentation

University of North Carolina, Chapel Hill1 site in 1 countryDecember 2013

Overview

Phase
Not Applicable
Intervention
Not specified
Conditions
Mammogram Scheduled
Sponsor
University of North Carolina, Chapel Hill
Locations
1
Primary Endpoint
Receiver Operative Curve (ROC) Area Under the Curve (AUC) (percentage)
Status
Withdrawn
Last Updated
7 years ago

Overview

Brief Summary

Purpose:The aim of this research is to compare the 3D s-DBT (stationary digital breast tomosynthesis) and conventional 2-D digital mammography devices with regards to patient comfort and radiologist preference in women with breast implants.

Participants: Women with breast implants undergoing routine 2-D digital mammography.

Procedures (methods): 50 female subjects with breast implants undergoing conventional screening mammography will be recruited to have a single view s-DBT in the mediolateral projection. We will perform a patient preference study and radiologist reader study composed of radiologists who have experience evaluating tomosynthesis images. A short survey will be given to each patient about their preference in modality with respect to comfort. Each reader will review the images and score the ease of interpretation, and their confidence of interpretation.

Detailed Description

Patients will be recruited with assistance from a referring physician and through patients undergoing routine mammography in the breast imaging clinic. All eligible women will be contacted by letter and/or phone call prior to scheduled mammography appointment to identify if they would be interested in participating in the research study. On the day of their conventional mammographic imaging, the study will be explained, and they will be offered the opportunity to participate. Consent will happen in a private room in the mammography clinic. Once consent has been signed, a urine sample will be collected from women who can still become pregnant in order to complete a pregnancy test. Women who are pregnant are unable to participate in this study. Women who consent for the study will be escorted by the research coordinator to a dressing room, where the subject will change into a gown. The research coordinator or research technologist will then escort the participant to the dedicated study room for the imaging exam. The patient will have the SDBT study performed in a similar manner as conventional mammography in the mediolateral oblique and cranio-caudal plane. The participant will stand up and the mammography research technologist, ensuring patient comfort, will assist in positioning their breast in the breast tomosynthesis unit with standard compression. Once positioned, the total scan time is approximately 10 seconds. Both the left and right breast will be imaged. The length of time for the positioning and examination of a subject's breast may vary but it is expected that the entire imaging procedure will take about 5-10 min, including positioning time. The breast tomosynthesis scan will be acquired at a dose that is equal to or less than a diagnostic mammogram dose. Upon completion of the breast tomosynthesis exam, the research assistant will provide a short survey to be completed by the patient (less than 5 minutes). The survey will include questions such as the comfort level of s-DBT compared to the standard mammography. The research SDBT exam will NOT be interpreted prior to the patient leaving the clinic. However, since there is theoretically a possibility of detecting an additional lesion not seen on conventional mammography, all images will be reviewed within a week by a qualified breast imaging specialist. If there are lesions of concern, these will be discussed with the referring surgeon or the patient's primary physician. After completion of the patient acquisition, a reader study will be performed with five qualified radiologists.

Registry
clinicaltrials.gov
Start Date
December 2013
End Date
October 3, 2017
Last Updated
7 years ago
Study Type
Interventional
Study Design
Single Group
Sex
Female

Investigators

Responsible Party
Sponsor

Eligibility Criteria

Inclusion Criteria

  • Women at least 18 years old.
  • Able to provide informed consent.
  • History of breast augmentation mammoplasty (at least 1 year prior)

Exclusion Criteria

  • Male. (It is uncommon for men to present for breast imaging)
  • Less than 18 years of age.
  • Patient unable to give consent. Institutionalized subject (prisoner or nursing home patient).
  • Any woman who is pregnant or has reason to believe she is pregnant or any woman who is lactating
  • Patient with a history of breast cancer (they would not be a screening exam)
  • Patient with a known breast cancer (they would not be a screening study)
  • Patient with a lump or nipple discharge (diagnostic population)

Outcomes

Primary Outcomes

Receiver Operative Curve (ROC) Area Under the Curve (AUC) (percentage)

Time Frame: 18 months

Receiver Operative Curve (ROC) Area Under the Curve (AUC) analysis of the stationary breast tomosynthesis (SDBT) system for the the characterization of suspicious breast lesions in comparison to x-ray mammography.

Secondary Outcomes

  • Reader preference - arbitrary units(18 months)
  • Patient preference - arbitrary units(18 months)

Study Sites (1)

Loading locations...

Similar Trials