Speech Effects of a Speaking Valve Versus External PEEP in Tracheostomized Ventilator-Dependent Neuromuscular Patients
试验速览
- 阶段
- 2 期
- 状态
- 已完成
- 发起方
- 入组人数
- 10
- 试验地点
- 2
- 主要终点
- text reading duration
研究概览
简要总结
Background:
Many patients with respiratory failure related to neuromuscular disease receive chronic invasive ventilation through a tracheostomy. Improving quality of life, of which speech is an important component, is a major goal in these patients. The investigators compared the effects on breathing and speech of low-level positive end-expiratory pressure (PEEP, 5 cm H2O) and of a Passy-Muir speaking valve (PMV) during assist-control ventilation.
Methods:
Flow will be measured using a pneumotachograph. Microphone speech recordings were subjected to both quantitative measurements and qualitative assessments; these last consisted of a perceptual score and an intelligibility score determined by two speech therapists using a French adaptation of the Frenchay Dysarthria Assessment.
详细描述
METHODS
Patients 10 ventilator-dependent patients with neuromuscular disease. All patients will receive mechanical ventilation via a cuffless tracheostomy. The study protocol was approved by our institutional review board, and written informed consent will be obtained from all patients before study inclusion.
Experimental setup Ventilator-delivered flow will be measured using a pneumotachograph (Fleisch #2, Lausanne, Switzerland) and tracheal pressure at the proximal end of the tracheostomy tube using a differential pressure transducer (Validyne MP 45±100 cm H2O, Northridge, CA, USA). To assess patient gas exchange, oxygen saturation (SpO2) will be estimated using pulse oximetry (Ohmeda Biox, BOC Healthcare, Boulder, CO, USA).
Acoustic speech signals will be recorded using three methods. The signals recorded from a microphone (DM202, MDE, Pierron, Sarreguemines, France) positioned 20 cm from the patient's lips were routed to a microcomputer with an AD converter (MP150® and Acqknowledge®, Biopac system, Goleta, CA, USA) that synchronized respiratory data (ventilator flow and tracheal pressure) and acoustic data. The AD converter will digitize respiratory signals at 128 Hz and speech signals at 20 000 Hz. The acoustic signal will be also routed to the Dragon NaturallySpeaking 10® speech recognition system (Nuance; Burlington, MA, USA) with its specific microphone and a laptop computer containing its speech recognition software. Finally, the acoustic signal will be recorded on a digital recorder (DS55, Olympus®, Herodphot, Manage, France) with a signal bandwidth between 50 and 19 000 Hz to allow assessment of fundamental frequency and subsequent qualitative analysis by speech therapists.
Experimental protocol All patients will be receiving ACV, the ventilation mode used in all tracheostomized patients followed at our neuromuscular unit. VI, TI, backup rate, and inspiratory trigger sensitivity will be kept unchanged. Before testing, patients will be familiarized with the use of 5 cm H2O PEEP and of the PMV. These two conditions will be tested in random order. With each condition, the patient first will use the Dragon NaturallySpeaking 10® voice-training menu, which involves reading a text passage for 10 minutes to enable software training. Then, the patient will continuously utter the [a] sound for as long as possible, read a list of words, utter the [a] sound in a glissando from high pitch to low pitch then from low pitch to high pitch, and read a standard text passage.
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Crossover
- 主要目的
- Supportive Care
- 盲法
- Single (Outcomes Assessor)
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Neuromuscular patients
- •Patients received mechanical ventilation via a cuffless tracheostomy
排除标准
- •Acute respiratory failure
结局指标
主要结局
text reading duration
时间窗: 1 hour
次要结局
- respiratory comfort(1 hour)
- speech comfort(2 hours)
- Dragon NaturallySpeaking 10® system ability to recognise the speech(30 minutes)
- Sustained [a] duration(15 minutes)
- perceptual score and intelligibility score determined by 2 blinded speech therapists(2 hours)