"Efficacy of Hybrid Systems ("Topping Off") Versus Rigid Spinal Fusion in Lumbar Fusion Surgery: A Dual-center, Prospective, Randomized Pilot Study ("CD Horizon BalanC")"
Not Applicable
- Conditions
- Spine Surgery
- Interventions
- Device: CD HORIZON BalanC™ MedtronicDevice: Solera™ Medtronic
- Registration Number
- NCT02551302
- Lead Sponsor
- University of Cologne
- Brief Summary
Effectiveness of hybrid systems ("topping off") compared to rigid spondylodesis in fusion surgery of the lumbar spine: A prospective, randomized, bicentric pilot study ("CD HORIZON BalanC™)
- Detailed Description
Posterior spondylodesis and monosegmental intervertebral cage plus flexible spondylodesis of the superiorly adjacent segment (CD HORIZON BalanC™ Manufacturer: Medtronic)
Control:
Posterior spondylodesis and monosegmental intervertebral cage
Recruitment & Eligibility
- Status
- UNKNOWN
- Sex
- All
- Target Recruitment
- 60
Inclusion Criteria
- Informed consent
- Legal capacity
- Age ≥ 30 years
- Indication for monosegmental lumbar spine fusion (PLIF or "topping-off ") L2-S1 with osteochondrosis Modic grades I-III [20][21][22] or spondylolisthesis Meyerding grades I-III.
- Radiologic signs of degeneration in the adjacent segment of the intended fusion without signs of instability
Exclusion Criteria
- Motor deficit
- Cauda equina syndrome
- Previous surgical intervention of the lumbar spine
- Relevant peripheral neuropathy
- Acute denervation subsequent to a radiculopathy
- Scoliosis with Cobb angle greater than 25°
- Spondylolisthesis > Meyerding grade III
- Radiologic signs of degeneration in the adjacent segment of the intended fusion with signs of instability (for definition, see inclusion criteria)
- No radiologic signs of degeneration in the adjacent segment of the intended fusion (for definition, see inclusion criteria)
- Radiologic signs of degeneration in the adjacent segment of the intended fusion with >Fujiwara grade II [15] or >Pfirrmann grade IV [14]
- Signs of instability in any lumbar spine segment other than that undergoing fusion
- General contraindication for elective lumbar spine surgery
- Pathologic fracture
- Osteoporosis with pathologic fracture
- Active systemic infection
- Rheumatic disease
- Disease of bone metabolism (e.g. Paget's Disease)
- Bone metastasis
- Local infection focus lumbar spine
- Seizure disorder
- Chronic ischemia Fontaine classification IIb-IV
- Severe heart insufficiency (NYHA III-IV)
- Blood coagulation disorder or blood thinning therapy
- Cortisone intake more than one month in the last 12 months before randomization
- Simultaneous participation in another clinical trial in the 30 days before randomization
- Known allergy or intolerance to the implants
- Dependency on investigator
- Lack of familiarity with the German language
- Placement in an institution by governmental or juridical advice
- Absent legal capacity
- Pregnancy
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- PARALLEL
- Arm && Interventions
Group Intervention Description Hybrid system (PLIF + flexible pedicle screw system above the CD HORIZON BalanC™ Medtronic The intervention group will receive a hybrid system with a PLIF and a flexible pedicle screw system above the fusion. PLIF Solera™ Medtronic The control group will receive a monosegmental posterior lumbar spine fusion with an intervertebral cage (PLIF).
- Primary Outcome Measures
Name Time Method Changes in the subscores of physical pain and physical function in the ODI Questionaire Baseline to 6 month
- Secondary Outcome Measures
Name Time Method MCS and individual dimensions and subscales of the SF-36™ 60 Month