Reduction of Shear Forces Using Semi-flexible Sockets on Transtibial Amputees
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 5
- 试验地点
- 2
- 主要终点
- Balance
研究概览
简要总结
The purpose of this graduate student research study, is to test two different sockets for comfort and test what pressures are created by the socket during daily activities. The objective is to illustrate that semi-flexible sockets will maintain its rigidity and resist progressive shear forces from daily activity, ergo making our prosthetic system a more comfortable experience for the prosthetic user.
详细描述
Subjects will immediately be prepared for a casting of their residual limb. On the second visit, subjects will return to be fitted with a definitive rigid carbon fiber socket. At this time, a questionnaire and physical assessments will determine subjects comfort and safety. The physical assessment consists of a ten minute walk on a treadmill, at a self-selected pace. A balancing test on a SMART Balance Master will also be used to assess subject safety, by utilizing the limits of stability protocol. Subjects' will be required to wear the prosthesis given to them for one week before returning for a follow-up appointment. On the third visit, the subjects' will return the first prosthesis to the investigators of the study, where an additional socket will be given to the subject for the second portion of this study. Subjects will be evaluated with a questionnaire and physical assessments to determine comfort and safety. Participants will be required to wear the prosthesis given to them for one week before returning for a follow-up appointment. During the final appointment, the subjects will return all devices given to them to an investigator of the study.
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Crossover
- 主要目的
- Other
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 是
入选标准
- •Transtibial amputee with mature limb
- •Minimum of 3-years of prosthetic use
- •Capable of ambulating on a treadmill for ten minutes
- •Minimum age of 18 years old
- •Both Unilateral and Bilateral Amputees
- •K-Level K2-K4
排除标准
- •Any open wounds/ulcerations on the residual limb
- •Skin allergies to silicone or latex
- •Unmanaged co-morbidities such a diabetes and congestive heart failure
结局指标
主要结局
Balance
时间窗: Change in balance between Week 2 and Week 3 of study
The SMART Balance Master is a device used to measure balance. It consists of a plate with force sensors that can measure the subject's center of gravity as the subject shifts their position back and forth through the exercise. We will be exerting the subjects through the different phases of gait also known as a Limits of Stability test, one of the many pre-programed tests available to choose from.The SMART Balance Master is a widely used device in the rehabilitation world to test an individual's balance and ascertain their functional limits. It is a device that has great repeatability and is used to test individuals rehabilitation progress. It is also used extensively in research due to its high reproducibility. The SMART Balance Master is manufactured by Natus Medical Incorporated which is located in Pleasanton California.
次要结局
- Socket liner integrity(Change in socket liner between Week 2 and Week 3 of study)
研究者
Gurinder Bains
Associate Professor
Loma Linda University