Feasibility of a Minimally Invasive Image-Guided Surgery System for Hepatic Procedures
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 发起方
- 入组人数
- 20
- 试验地点
- 1
- 主要终点
- The number of accepted liver registrations associated with laparoscopically acquired surface data compared with the number of accepted liver registrations associated with open liver acquired surface data.
研究概览
简要总结
This study was designed to confirm that the surgeon is able to perform surface registration of standard liver features used as landmarks during a scheduled laparoscopic liver procedure. Additionally, registrations will be obtained with full insufflation pressure and with half insufflation pressure during the laparoscopic procedure. Under the presence of both insufflation pressures, the surface of the liver will be manually swabbed with the study tracked laparoscopic probe with landmarks noted during data collection. After registration of the liver is obtained, the registration points obtained during this procedure will be evaluated by the surgeon by moving the tracked laparoscopic probe over the liver surface and evaluating the location of the tracked laparoscopic probe displayed on the guidance system 3D image. The surgeon will accept or reject the registration accuracy. Upon completion of the scheduled laparoscopic procedure, the subject will then undergo the open procedure scheduled for the surgical case. An open liver registration will be obtained with manual swabbing of the liver using the study tracked probe and will be accepted or rejected by the surgeon using the process described in the laparoscopic procedure.
In the event that the disease is determined to be too great for surgical repair during the laparoscopic staging procedure, only minimally invasive liver surface data will be acquired and the patient will not be included in the overall study population.
详细描述
The Pathfinder System used during this study is used for data collection purposes only and is not used during the surgical procedure as an image guided system.
Preoperative CT scans, obtained as standard of care, will be used to generate the image guided liver system 3D liver surface images used during the study.
During the laparoscopic procedure, the Pathfinder device will be inserted through the standard laparoscopic ports (5mm or 10mm) being used for the staging procedure.
For the purposes of the study, subjects will be enrolled following the inclusion/exclusion criteria below:
Inclusion:
研究设计
- 研究类型
- Observational
- 观察模型
- Case Only
- 时间视角
- Prospective
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Clinical Diagnosis of Liver Cancer
- •Scheduled for liver surgery
排除标准
- •Receiving a liver transplant
- •Kidney failure or dialysis
- •Unable to consent
结局指标
主要结局
The number of accepted liver registrations associated with laparoscopically acquired surface data compared with the number of accepted liver registrations associated with open liver acquired surface data.
时间窗: 30 Days
Subjects are followed for the study 30days (+/- 14 days) and are considered to have completed the study following this 30 day follow-up visit.
次要结局
- Comparison of registration errors from the full and half sufflation pressures to determine an impact of insufflation pressure on registration accuracy.(30 Days)