Skip to main content
Clinical Trials/NCT05991271
NCT05991271Not yet recruitingNot Applicable

Multicenter Pivotal Study to Evaluate the Treatment of Severe Aortic Valve Stenosis With Next-Generation Venus-Vitae Transcatheter Heart Valve (THV) System

Venus MedTech (HangZhou) Inc.0 sites150 target enrollmentStarted: October 31, 2023Last updated:
Conditions
Interventions

Trial Snapshot

Phase
Not Applicable
Status
Not yet recruiting
Enrollment
150
Primary Endpoint
The rate of deaths at the one-year follow-up visit post procedure

Study Overview

Brief Summary

The purpose is to evaluate the safety, effectiveness and performance of Venus-Vitae Transcatheter Heart Valve System in patients with severe aortic stenosis.

Detailed Description

This trial is a prospective, multi-center, non-randomized interventional study to evaluate the safety, effectiveness and performance of the Venus-Vitae Transcatheter Heart Valve System in patients with severe aortic stenosis. Clinical visits will be scheduled at screening, pre-discharge, 30 days, 6 months, 12 months and annually thereafter to 5 years.

Study Design

Study Type
Interventional
Allocation
Na
Intervention Model
Single Group
Primary Purpose
Treatment
Masking
None

Eligibility Criteria

Ages
18 Years to — (Adult, Older Adult)
Sex
All
Accepts Healthy Volunteers
No

Inclusion Criteria

  • •Age ≥ 18 years
  • •Patients with the symptoms of severe aortic stenosis
  • •Severe aortic stenosis (AS, grade 3+), defined as AVA ≤ 1 cm2 (AVAi ≤ 0.6 cm2/m3) or Vmax ≥ 4.0 m/s or MPG ≥ 40 mmHg determined by echocardiography
  • •Patients deemed for cardiac intervention by a heart team
  • •Patients of all surgical risk categories can be enrolled in this study, but should follows local medical practices and regulatories.
  • •Patients or their legal reprensentatives are willing to participate in the study and provide written informed consent, and agree to follow the follow-up requirements

Exclusion Criteria

  • •A subject meeting any of the following criteria shall be excluded:
  • •Co-morbidities
  • •Previous mechanical or biological aortic valve replacement
  • •Untreated mitral, tricuspid or pulmonary valve diseases requiring procedural intervention
  • •Acute myocardial infact within 30 days prior to index procedure
  • •Untreated clinical significant coronary artery disease requiring revascularization
  • •Any therapeutic invasive cardiac procedure performed within 30 days (or drug-eluting coronary stent/scaffold implant within 6 months)
  • •Sever symptomatic carotid artery stenosis
  • •Stroke or TIA within 3 months or Modified Rankin Scale ≥ 4 disability
  • •Chronic kidney disease (eGFR<30 mL/min/1.73m2)
  • •Haemotologic disorders: Leukopenia (WBC < 3000 cell/mL), anemia (Hgb < 9 g/dL), thrombocytopenia (Plt< 50,000 cell/mL), or any known blood clotting disorder, deemed clinically significant after consultation with Haematooncology specialists
  • •Severe right heart dysfunction Anatomical
  • •LVEF < 20%
  • •Echocardiographic evidence of intracardiac mass, thrombus, or vegetation
  • •Inappropriate anatomy for femoral introduction and delivery of study device
  • •Native aortic valve geometry and size unfavorable for study device anchoring General
  • •Haemodynamics instability requiring inotropic support or intra-aortic balloon pump (IABP) or other hemodynamic support device, or any mechanical heart assistance
  • •Known hypersensitivity or contraindication to antiplatelet, antithrombotic medications, or cobalt-chromium leading to be unable to undergo index procedure per physicians' judgement
  • •Life expectancy ≤ 1 year due to noncardiac reasons
  • •Active infection requiring antibiotic therapy including infective endocarditis
  • •Planned relevant concomitant procedure within 30 days post index procedure
  • •Pregnant, breastfeeding or intend to become pregnant within 1 year

Arms & Interventions

procedure

Experimental

implant valve by TAVR

Intervention: Venus-Vitae Transcatheter Heart Valve System (Device)

Outcomes

Primary Outcomes

The rate of deaths at the one-year follow-up visit post procedure

Time Frame: 1 Years

All-cause mortality (The rate of deaths at the one-year follow-up visit post procedure)

Acceptable Hemodynamic Performance at 30 days

Time Frame: 30 Days

Acceptable Bio-prosthesis Hemodynamic Performance at 30 days, defined as: * Mean gradient \< 20mmHg * Less than moderate aortic regurgitation (perivalvular and transvalvular)

Secondary Outcomes

  • The rate of freedom from mild or greater commissure misalignment assessed by post-implant angiogram and/or 30-day CT(30-Days)
  • Technical success is defined as the following(During the Procedure)
  • The rate of device success is defined as the following(Up to 1 week)
  • The rate of acceptable valve function at pre-discharge by echocardiogram defined as the following:(Up to 1 week)
  • New York Heart Association (NYHA) classification during follow-up(5 Years)
  • The rate of freedom from mild or greater PVL by echocardiogram during follow-up(5 Years)
  • Occurrence of the following adverse events echocardiogram during follow-up(5 Years)
  • The rate of freedom from severe coronary overlap assessed by post-implant angiogram(immediately after the procedure)

Investigators

Sponsor Class
Industry
Responsible Party
Sponsor

Similar Trials