Patient Satisfaction for Digital Versus Conventional Maxillary Obturator
- Conditions
- Maxillofacial Prosthesis User
- Interventions
- Other: conventional obturatorOther: 3 d printed obturator
- Registration Number
- NCT05920811
- Lead Sponsor
- Tanta University
- Brief Summary
Evidence regarding the performance of digital obturators totally fabricated using 3D printing is insufficient. This prospective randomized crossover study aimed to evaluate patient satisfaction with conventional maxillary obturator and totally full digitally fabricated obturator. Patient satisfaction was evaluated using two scales: The Obturator Functioning Scale" and "The Patient and operator-centered outcomes were assessed through two visual analog scale (VAS) questionnaires.
- Detailed Description
The use of digital technologies in the fabrication of maxillofacial prostheses has been described. Additive manufacturing offers a more convenient and more efficient process with reduced material waste compared with traditional subtractive technique. Although Prosthetic rehabilitation with Conventional maxillary obturator prosthesis fabricated with a casted metal framework using, heat-cured acrylic resin can restore oral function and facial esthetics following maxillectomy. But it is time-consuming and labor-intensive. Multiple sources of errors can accumulate during the laboratory steps, resulting in a misfit of the framework. In this study All patients received a conventional obturator for 6 months, after a washout period of one week, they use the digital one. The Obturator Functioning Scale" and "The Patient and operator-centered outcomes were assessed through two visual analog scale (VAS) questionnaires.
Recruitment & Eligibility
- Status
- COMPLETED
- Sex
- All
- Target Recruitment
- 10
- patients with hemimaxillectomy defect (Aramany class 1)
- almost edentulous mandible with healthy remaining teeth,
- mouth opening is not less than 25 mm, intact soft palate
- participants were not exposed to radiotherapy or chemotherapy in the previous year
- patients with physical or mental disorders.
- patients still receiving radio or chemotherapy
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- CROSSOVER
- Arm && Interventions
Group Intervention Description conventional obturator conventional obturator maxillary obturator fabricated from cast metal framework, heat-cured acrylic resin 3 d printed obturator 3 d printed obturator 3d printed obturator with full digital workflow ( intraoral scanning, made of selective laser melting, 3d printed resin
- Primary Outcome Measures
Name Time Method obturator functioning scale 6 months The Obturator Functioning Scale ( minimum value is "1"and maximum value is "5"
patient outcome the treatment time, on the self-perception of the applied impression protocol in terms of general convenience, anxiety, taste, nausea sensation and possible pain sensation. 6 months questions focused on general convenience, anxiety, taste, nausea sensation and possible pain sensation, assessed through visual analogue scale (VAS)
operator outcome 6 months Questions focused on the treatment time, on the self-perception of the applied impression
- Secondary Outcome Measures
Name Time Method
Trial Locations
- Locations (1)
marwa Mohammed Amer
🇪🇬Tanta, ElGharbia, Egypt