跳至主要内容
临床试验/NCT04296617
NCT04296617已完成不适用

Assessment of Predicted LET and Dosimetry in Relation to White Matter Changes in Pediatric Patients Following Proton Therapy for Primary Central Nervous System and Base of Skull Malignancies: A Pilot Study

Mayo Clinic1 个研究点 分布在 1 个国家目标入组 36 人开始时间: 2019年1月21日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
Mayo Clinic
入组人数
36
试验地点
1
主要终点
White matter changes within the central nervous system (CNS) following proton beam therapy using magnetic resonance imaging (MRI) sequences

研究概览

简要总结

This trial gathers information from patients with primary central nervous system or base of skull tumors that receive proton beam therapy and see if certain imaging techniques can help detect radiation-related changes over time. This study may help providers learn more about proton beam radiotherapy and how to improve the way it is delivered.

详细描述

PRIMARY OBJECTIVE:

I. To establish linear energy transfer (LET)-based models as early predictors for white matter changes on magnetic resonance imaging (MRI) and diffusion tensor imaging (DTI) sequences in pediatric patients following proton beam therapy for primary central nervous system (CNS) and base of skull tumors.

OUTLINE:

Patients' medical charts are reviewed.

研究设计

研究类型
Observational
观察模型
Case Only
时间视角
Prospective

入排标准

年龄范围
— 至 21 Years(Child, Adult)
性别
All
接受健康志愿者

入选标准

  • Patients must have histologically confirmed central nervous system of skull base tumors
  • Patient is going to undergo central nervous system (CNS) or base of skull proton beam therapy

排除标准

  • Patients who have received prior therapeutic radiotherapy to the primary brain tumor site
  • Patients who are unable to maintain follow-up through the Phoenix Children's Hospital and Mayo Clinic Arizona

结局指标

主要结局

White matter changes within the central nervous system (CNS) following proton beam therapy using magnetic resonance imaging (MRI) sequences

时间窗: At 18 months

The concordance of predicted linear energy transfer linear (LET) values with radiographic white matter changes will be analyzed utilizing a one sample t-test. Will the compare concordance over time to evaluate if there is an increase, utilizing repeated measures mixtures models.

Relative biological effectiveness (RBE) predictions

时间窗: Up to 18 months

Will compare concordance over time to evaluate if there is an increase, utilizing repeated measures mixtures models.

White matter changes within the CNS following proton beam therapy using diffusion tensor imaging (DTI) sequences

时间窗: At 18 months

The concordance of predicted LET values with radiographic white matter changes will be analyzed utilizing a one sample t-test. We will the compare concordance over time to evaluate if there is an increase, utilizing repeated measures mixtures models.

次要结局

  • White matter changes identified on imaging, and predict concordance(Up to 18 months)
  • White matter changes within the CNS following proton beam therapy using DTI and MRI(Up to 18 months)
  • Dose-volume effect and predicted LET distribution(Up to 18 months)

研究者

发起方
Mayo Clinic
申办方类型
Other
责任方
Sponsor

研究点 (1)

Loading locations...

相似试验