A Comparative study of 2D Echocardiography and CT Pulmonary angiography for detection of complex congenital heart disease in pediatric population - A one-year cross-sectional study at tertiary care center
概览
- 阶段
- 不适用
- 状态
- 尚未招募
- 发起方
- DR MIR SAJID RAZA
- 入组人数
- 40
- 试验地点
- 1
- 主要终点
- To compare the diagnostic accuracy of two-dimensional echocardiography (2D Echo) and computed tomography (CT)pulmonary angiography in detecting complex CHD in children
概览
简要总结
This study is a comparative cross sectional investigation designed to evaluate the diagnostic accuracy of 2D Echocardiography and CT Pulmonary Angiography in detecting complex congenital heart disease in the pediatric population at a tertiary care center over one year. Congenital heart disease is a leading cause of morbidity and mortality in children, and early diagnosis is crucial for improving survival, treatment outcomes, and quality of life. 2D Echocardiography is the standard first line diagnostic tool due to its safety and radiation free nature. However, it has limitations in assessing extra cardiac vascular structures and is highly operator dependent. CT Pulmonary Angiography, with its three dimensional imaging and high spatial resolution, provides accurate anatomical assessment of intra and extra cardiac structures, thereby enhancing preoperative planning and overall management. The study aims to compare these two modalities to determine their relative effectiveness, accuracy, and utility in clinical decision making for pediatric congenital heart disease for the study.
研究设计
- 研究类型
- Observational
入排标准
- 年龄范围
- 1.00 Day(s) 至 18.00 Year(s)(—)
- 性别
- All
入选标准
- •Pediatric patients under 18 years of age with: Complex cyanotic congenital heart disease with difficult PA anatomy.
- •Complex cyanotic heart defect with poor ECHO window.
- •Complex aberrant pulmonary vein drainage and an unusual type of TAPVC Rare cases of abnormal systemic venous drainage, pulmonary arterio-venous fistula, and pulmonary thromboembolism are suspected.
排除标准
- •Patients with renal failure in whom serum creatinine is higher, and contrast administration is not advisable.
- •Those who have undergone diagnostic cardiac catheterisation and pulmonary artery anatomy have been well defined.
- •Complex cyanotic congenital heart defects in whom ECHO can identify the anatomy without any ambiguity.
结局指标
主要结局
To compare the diagnostic accuracy of two-dimensional echocardiography (2D Echo) and computed tomography (CT)pulmonary angiography in detecting complex CHD in children
时间窗: one year
次要结局
- To know the correlation between the findings on two-dimensional echocardiography (2D Echo) and computed tomography (CT)pulmonary angiography with intra-operative findings.(one year)
研究者
DR MIR SAJID RAZA
Jawaharlal Nehru Medical College