跳至主要内容
临床试验/NCT06398574
NCT06398574
招募中
不适用

Effect of Dry Needling Technique on Shoulder Muscle Functionality in Subjects With and Without Shoulder Pain.

University of Alcala2 个研究点 分布在 1 个国家目标入组 40 人2024年5月6日

概览

阶段
不适用
干预措施
Real dry needling
疾病 / 适应症
Shoulder Pain
发起方
University of Alcala
入组人数
40
试验地点
2
主要终点
Muscle strength
状态
招募中
最后更新
昨天

概览

简要总结

The main objective of this study will be to evaluate the effects of the application of the dry needling technique on the activity of the rotator cuff muscles in the shoulder.

The evaluation of the effects of the application of the dry needling technique will be carried out in subjects with and without shoulder pain.To do this, muscle strength, possible thickness changes in the muscle and electromyographic activity will be measured before and immediately after the application of a dry needling technique.

Likewise, other variables will be measured such as the pressure pain threshold (PPT), pain with a Numeric Verbal Scale, kinesiophobia and catastrophism, the shoulder pain and disability index (SPADI) and the influence of expectations about dry needling.

注册库
clinicaltrials.gov
开始日期
2024年5月6日
结束日期
2026年12月20日
最后更新
昨天
研究类型
Interventional
研究设计
Parallel
性别
All

研究者

发起方
University of Alcala
责任方
Principal Investigator
主要研究者

Prof. Dr. Daniel Pecos Martín

Professor

University of Alcala

入排标准

入选标准

  • Subjects of legal age
  • Subjects without shoulder pain or with unilateral shoulder pain of \> 3 months duration.
  • Have shoulder mobility of 90º of abduction and at least 30º of glenohumeral external rotation.

排除标准

  • Have neck pain.
  • Having had trauma to the shoulder.
  • Having fibromyalgia.
  • Be pregnant.
  • Being afraid of needles.

研究组 & 干预措施

Real dry needling

With the subject lying supine, a dry needling technique will be applied to the infraspinatus muscle.

干预措施: Real dry needling

Sham dry needling

With the subject lying supine, a sham dry needling technique will be applied to the infraspinatus muscle, simulating the real procedure.

干预措施: Sham dry needling

结局指标

主要结局

Muscle strength

时间窗: Change from Baseline at 15 minutes.

The isometric strength will be assessed using a handheld dynamometer (Hand held dynamometer, MicroFET3; Hoggan Health Industries Inc.). The strength measures will included external rotation at 90° abduction in the prone position. The dynamometer will be placed just proximal to the just proximal to the styloid process of the wrist joint. Subjects will be asked to produce a 5-second maximal contraction. Muscular strength will be measured in kilograms

次要结局

  • Muscle function(Change from Baseline at 15 minutes.)
  • Shoulder Pain(Change from Baseline at 15 minutes.)
  • Pressure Pain Threshold (PPT)(Change from Baseline at 15 minutes.)
  • Disability(Change from Baseline at 15 minutes.)

研究点 (2)

Loading locations...

相似试验