MedPath

Validation of Modified AST

Completed
Conditions
Strength
Registration Number
NCT05146115
Lead Sponsor
University of Liege
Brief Summary

The objective of the study is the validate and to assess the reliability of a modified version of the Athetic Shoulder Test. The activity of peri-scapular muscles during the realization of the test will be assessed too.

Detailed Description

The study will be divided into two sessions. A time of 7-10 days will be provided between the two sessions of tests to limit the influence of sport and training on the results.

Session 1:

* Warm-up

* Realization of the Athletic Shoulder Test (with EMG captors on upper trapezius, lower trapezius and serratus anterior)

* Realization of the modified Athletic Shoulder Test (with EMG captors on upper trapezius, lower trapezius and serratus anterior)

Session 2:

* Warm-up

* Realization of the Athletic Shoulder Test (with EMG captors on upper trapezius, lower trapezius and serratus anterior)

* Realization of the modified Athletic Shoulder Test (with EMG captors on upper trapezius, lower trapezius and serratus anterior)

Recruitment & Eligibility

Status
COMPLETED
Sex
Male
Target Recruitment
20
Inclusion Criteria
  • to practice an overhead sport at least 5 hours a week
Exclusion Criteria
  • no shoulder pain
  • no history of shoulder pain
  • no history of shoulder surgery
  • no scoliosis or lower limb lengths differences

Study & Design

Study Type
OBSERVATIONAL
Study Design
Not specified
Primary Outcome Measures
NameTimeMethod
EMG activity of upper trapeziusduring the first session

EMG activity of upper trapezius will be measured with surface electrodes (Delsys Trigno)

EMG activity of lower trapeziusduring the first session

EMG activity of lower trapezius will be measured with surface electrodes (Delsys Trigno)

Strength of anteflexors in "I" positionChange from baseline to 10 days

The strength developped in the "I" position will be assessed with a force plateform and a handheld dynamometer

Strength of anteflexors in "Y" positionChange from baseline to 10 days

The strength developped in the "Y" position will be assessed with a force plateform and a handheld dynamometer

Strength of anteflexors in "T" positionChange from baseline to 10 days

The strength developped in "T" position will be assessed with a force plateform and a handheld dynamometer

EMG activity of serratus anteriorduring the first session

EMG activity of serratus anterior will be measured with surface electrodes (Delsys Trigno)

Secondary Outcome Measures
NameTimeMethod

Trial Locations

Locations (1)

Laboratoire d'Analyse du Mouvement Humain

🇧🇪

Liège, Belgium

© Copyright 2025. All Rights Reserved by MedPath