跳至主要内容
临床试验/NCT02033343
NCT02033343已完成不适用

Phase I Feasibility Study of Prostate Cancer Radiotherapy Using Realtime Dynamic Multileaf Collimator Adaptation and Radiofrequency Tracking (Calypso)

Royal North Shore Hospital1 个研究点 分布在 1 个国家目标入组 30 人开始时间: 2013年10月1日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
入组人数
30
试验地点
1
主要终点
Percentage of fractions being successfully delivered with Calypso-guided tracking.

研究概览

简要总结

The purpose of this study is to monitor movement of the prostate during radiotherapy and adjust the radiation beam to account for any motion seen. This will increase the radiation dose to the prostate and decrease the dose to the rectum and bladder.

详细描述

Prostate cancer now accounts for one third of all new cancer diagnoses in men and approximately 30% of men will have external beam radiotherapy as their primary local therapy. Prostate motion during radiotherapy can be divided into interfraction and intrafraction motion. Interfraction motion has been well established and has been largely overcome by daily online image verification with either ultrasound, online CT or implanted fiducial markers, however motion during the radiation beam on time (intrafraction motion) is not corrected and can be the cause of significant errors in radiation dose delivery.

The most common technology utilised in 2012 to allow prostate gating is the Calypso system. The Calypso system consists of implantable electromagnetic transponders, an array that contains source and receiver coils, computers for data analysis and display purposes, and an infrared camera system to localise the electromagnetic array in the treatment room. The array is placed over the patient, and the source coil in the array emit an electromagnetic signal that excites the transponders. Once the transponders are excited, the source coils are turned off and the receiver coils detect the signal emitted from the excited transponders. This process is repeated at a rate of 10 Hz, providing a realtime radiofrequency localisation of the prostate triangulating three implanted beacons. The current study will investigate using the continuous prostate positioning data from Calypso to integrate with the treatment beam delivery and allow real-time adaptation based on the prostate motion. This is called Realtime Dynamic Multileaf Collimator (DMLC) tracking. In this technique the multileaf collimator motion is altered in the gantry head in real time during beam delivery to account for the measured prostate motion.

The proposed study is examining the dosimetric impact of accounting for intrafraction motion with Calypso and DMLC tracking. We hypothesise the improvements in delivered prostate dose with DMLC tracking will be even greater than gating. This improved treatment delivery will ensure that the prostate cancer receives the appropriate dose and that normal tissues are spared from extra radiation.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Treatment
盲法
None

入排标准

年龄范围
35 Years 至 85 Years(Adult, Older Adult)
性别
Male
接受健康志愿者
否

入选标准

  • •Patients undergoing external beam radiotherapy at Northern Sydney Cancer Centre
  • •Histologically proven prostate adenocarcinoma
  • •Prostate Specific Antigen (PSA) obtained within 3 months prior to enrolment.
  • •Patient must be able to have Varian Calypso beacons placed in the prostate (if on anticoagulants, must be cleared by Local Medical Officer or cardiologist).
  • •ECOG performance status 0-2
  • •Ability to understand and the willingness to sign a written informed consent document.
  • •Body habitus enabling Calypso tracking (as per Calypso Determining a Patient's Localisation Designation & Orientation before implantation)
  • •Prostate dimension that allows leaf span with tracking margin of ±8mm

排除标准

  • •Previous pelvic radiotherapy
  • •Prior total prostatectomy
  • •Pacemaker
  • •Implantable defibrillator
  • •Insulin infusion pump
  • •Hip prosthesis
  • •Unwilling or unable to give informed consent
  • •Unwilling or unable to complete quality of life questionnaires.

研究组 & 干预措施

Real-time tracking & beam adjustment

Experimental

Prostate cancer radiotherapy using real-time tracking

干预措施: Prostate cancer radiotherapy using real-time tracking (Radiation)

结局指标

主要结局

Percentage of fractions being successfully delivered with Calypso-guided tracking.

时间窗: 2 years

The primary endpoint of this Pilot study is to evaluate the feasibility of implementing realtime adaptive radiotherapy using DMLC. This will be assessed as greater than 95% of fractions being successfully delivered (no equipment failures and tracking MLC follows beacons) with Calypso-guided tracking.

次要结局

  • Late toxicity(Up to five years)
  • Improvement in overall beam-target geometric alignment.(2 years)
  • Improvement in dosimetric coverage of prostate and normal healthy structures.(2 years)
  • Acute toxicity(Assessed up to 12 weeks post treatment)
  • Biochemical control(Up to five years)

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Professor Thomas Eade

Radiation Oncologist

Royal North Shore Hospital

研究点 (1)

Loading locations...

相似试验