Development of an Assay for Tacrolimus Blood Trough Measurement in Pediatric Heart Transplant Patients Using Volumetric Absorptive Microsampling (VAMS) and Stable-Labeled Isotope Dilution Tandem Mass Spectrometry.

Children's Hospital Medical Center, Cincinnati1 个研究点 分布在 1 个国家目标入组 16 人开始时间: 2019年10月7日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
入组人数
16
试验地点
1
主要终点
Accuracy of +/-10%

研究概览

简要总结

This is a feasibility study at a single site, Cincinnati Children's Hospital Medical Center. Patients who have undergone heart transplantation who meet eligibility requirements will be approached to participate in the study. The purpose of this study is to establish a reliable, home-based method for collecting samples as well as a standardized method for use of small-volume samples on both inpatients and outpatients.

研究设计

研究类型
Interventional
分配方式
Non Randomized
干预模型
Single Group
主要目的
Device Feasibility
盲法
None

入排标准

年龄范围
1 Year 至 21 Years(Child, Adult)
性别
All
接受健康志愿者
否

入选标准

  • •Pediatric, adolescent, or young adult patients ≥1 and ≤21 years of age
  • •Aim 1: All patients presenting for routine post-transplant care including, but not limited to: cardiac catheterization, cardiac biopsy, inpatient admission, or outpatient visits
  • •Aim 2: outpatient
  • •Currently taking tacrolimus

排除标准

  • •Non-English-speaking patients
  • •Unable to access overnight delivery services (Aim 2 only)

研究组 & 干预措施

Aim 1

Experimental

All patients presenting for routine post-transplant care including, but not limited to: cardiac catheterization, cardiac biopsy, inpatient admission, or outpatient visits. A convenience sample of 25 inpatient samples will be collected for Aim 1. Although the assay developed by the MSCF will be validated for accuracy, the purpose of Aim 1 is to test "real world" application of the Mitra Microsampler tubes against the gold standard of blood collected by venipuncture in a controlled setting. To accomplish this, consecutive inpatient heart transplant patients will be enrolled. That sample will be collected at the same time (+/- 15 minutes) as a clinically-indicated, appropriately-timed venipuncture for measurement of a tacrolimus trough and prior to the subject taking tacrolimus so as to represent a trough.

干预措施: Mitra Microsampler (Device)

Aim 2

Experimental

Outpatient. A convenience sample of 25 outpatients collecting 1-2 samples will be collected for Aim 2. For those who agree to participate, the parent/patient will be taught by a member of the team on how to use the Microsampler to collect blood from a finger stick. They will be provided with a kit for collection of up to 2 samples and will also be provided with appropriate shipping materials to return samples to CCHMC. Participants will then be instructed to collect a sample in the Mitra Microsampler via fingerstick. In addition to the process of collecting the sample in Aim 2, appropriately-aged participants and/or families will be asked to fill out a brief survey regarding sample collection. This will include questions about the ease or difficulty of performing the steps and tolerability of the procedure relative to past experiences with values obtained by venipuncture.

干预措施: Mitra Microsampler (Device)

结局指标

主要结局

Accuracy of +/-10%

时间窗: 18-24 months from start of enrollment

A VAMS-based tacrolimus trough values will be accurate +/-10% when compared with standard whole blood values achieved via venipuncture.

次要结局

未报告次要终点