跳至主要内容
临床试验/NCT04172428
NCT04172428已完成不适用

Comparison of Compact 3T, Conventional 3T, and 7T Scanners Using Task Based and Resting State fMRI

Mayo Clinic1 个研究点 分布在 1 个国家目标入组 10 人开始时间: 2021年2月9日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
Mayo Clinic
入组人数
10
试验地点
1
主要终点
Statistical maxima of fMRI language and motor area activations.

研究概览

简要总结

Comparison of 3 MRI scanners.

详细描述

Comparing the strengths and weaknesses of 3 different MRI scanners in their performance of a functional MRI (an MRI that shows which areas in the brain are active during some sort of task).

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
18 Years 至 55 Years(Adult)
性别
All
接受健康志愿者

入选标准

  • Men and Women aged 18-55

排除标准

  • Patients with safety contraindications to MRI scanning at 3T.
  • Patients unable to adequately perform the fMRI task due to physical, neurological, or cognitive disability.
  • Patients that demonstrate 3 mm or greater translational head motion during scanning of the fMRI rhyming task data sets.
  • Pregnant women.
  • Patients that have implanted medical devices or other safety contraindications for a 7T or 3T MRI exam.

结局指标

主要结局

Statistical maxima of fMRI language and motor area activations.

时间窗: Approximately 6 months after last subject is scanned

For the task-based fMRI comparison, a region of interest will be drawn around activation maps overlying Broca's and Wernicke's language areas as well as the hand motor area. The data regarding each of the three regions will be treated separately. The statistical maxima for functional activation within these areas will be measured and compared using the same areas and technique on the three scanner platforms to determine which is the highest. This will be performed using the PRISM software we already use clinically to interpret fMRI.

Signal to noise ratio assessment of resting state.

时间窗: Approximately 6 months after last subject is scanned

For the resting state fMRI comparison, a standard measurement of signal to noise ratio will be employed specifically using the default mode network. This data will be reported separately from the task based outcome #1 as they are unrelated. Because this is a ratio is has no units of measurement.

次要结局

  • Neuroradiologist preference for scanner array.(Approximately 6 months after last subject is scanned)

研究者

发起方
Mayo Clinic
申办方类型
Other
责任方
Principal Investigator
主要研究者

David F. Black

Principal Investigator

Mayo Clinic

研究点 (1)

Loading locations...