Comparison Of Ultrasound-Based Measures Of Inferior Vena Cava And Internal Jugular Vein For Prediction Of Hypotension During Induction Of General Anesthesia
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 133
- 试验地点
- 1
- 主要终点
- Comparison of the accuracy of IVC and IJV variations in prediction of prolonged post-induction hypotension.
研究概览
简要总结
Hypotension after induction of general anesthesia is a frequent event in routine practice. Even a short period of hypotension may lead to tissue hypoperfusion and predispose to postoperative complications. Intra-operative hypotension is associated with renal injury, ischemic stroke, myocardial injury and postoperative mortality in patients having non-cardiac surgery under general anesthesia. Underlying hypovolemia is an important and modifiable risk factor for hypotension after anesthetics administration. Ultrasonographic studies of the inferior vena cava (IVC) and the internal jugular vein (IJV) for evaluation of intravascular volume status and prediction of hypotension during induction of general anesthesia have been established.
The present study was designed to compare, on ultrasound-based measures, between inferior vena cava and internal jugular vein for prediction of prolonged hypotension during induction of general anesthesia. The study was conducted at Kasr Al-Ainy hospital, Cairo University in Patients undergoing elective non-cardiac surgery under general anesthesia.
详细描述
Upon arrival to the operating room, routine monitors in the form of pulse oximetry, electrocardiogarm and non-invasive blood pressure monitors were applied. Intravenous line was secured and routine premedications (ranitidine 50 mg and ondansetron 4 mg) were administered.
IVC evaluation was done for the patients in the supine position. The examination was performed after 5 minutes rest. A curved ultrasound transducer set to abdominal mode (1-5 MHz; Acuson x300; Siemens Healthcare, Seoul, Korea) was placed in the subcostal area to visualize the IVC in the paramedian long-axis view. The IVC was visualized using two-dimensional mode as it enters the right atrium; then, pulse wave doppler was used to differentiate the IVC from the aorta. Respiratory variations of the IVC diameter were evaluated using M-mode imaging at medium sweep speed 2 to 3 cm distal to the right atrium. The measures were obtained 3 times and their average was calculated. Maximum and minimum IVC diameters over a single respiratory cycle were used to calculate the collapsibility index as follows:
(dIVCmax- dIVCmin)/dIVCmax Collapsibility index was expressed as a percentage.
IJV measurements were obtained in the supine position using a linear ultrasound transducer (5 - 13 MHz; Acuson x300; Siemens Healthcare, Seoul, Korea). The probe was placed horizontally at the middle level of the thyroid cartilage. After obtaining a clear transverse view of the right IJV, the IJV area was measured. The measures were repeated after changing the patient's position to the 10° Trendelenburg position. The maximum area of the IJV in the supine and Trendelenburg positions was recorded and the rate of change in IJV area was calculated as follows:
IJV change rate with posture = (IJV area in Trendelenburg position - IJV area in supine position)/(IJV area in Trendelenburg position) All ultrasonographic measurements were performed by a single trained anesthesiologist.
研究设计
- 研究类型
- Observational
- 观察模型
- Case Only
- 时间视角
- Cross Sectional
入排标准
- 年龄范围
- 18 Years 至 50 Years(Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Patients aged 18 - 50 years old
- •Any scheduled non-cardiac surgery under general anesthesia
- •ASA I, II
排除标准
- •Patients with major vascular disease
- •Unstable angina
- •Ejection fraction < 40 %
- •Respiratory distress
- •Increased intra-abdominal pressure.
- •Diabetes mellitus
- •Implanted pacemaker
- •Patients on ACEI or ARB
- •Anticipated difficult intubation
结局指标
主要结局
Comparison of the accuracy of IVC and IJV variations in prediction of prolonged post-induction hypotension.
时间窗: Intra-operative along the time of the study
Comparison of the accuracy (area under receiver operating characteristic curves) of IVC and IJV variations in prediction of prolonged post-induction hypotension (defined as MBP \< 80% of the baseline reading for 2 minutes or more).
次要结局
- Incidence of prolonged post-induction hypotension.(Intra-operative along the time of the study)
- The accuracy of maximum diameter of IVC in predicting prolonged post-induction hypotension.(Intra-operative along the time of the study)
- The accuracy of minimum diameter of IVC in predicting prolonged post-induction hypotension.(Intra-operative along the time of the study)
- The accuracy of IVC collapsibility index in predicting prolonged post-induction hypotension.(Intra-operative along the time of the study)
- The accuracy of IJV area in supine position in predicting prolonged post-induction hypotension.(Intra-operative along the time of the study)
- The accuracy of IJV area in Trendelenburg position in predicting prolonged post-induction hypotension.(Intra-operative along the time of the study)
- The accuracy of IJV change rate in predicting prolonged post-induction hypotension.(Intra-operative along the time of the study)
- Incidence of severe post-induction hypotension.(Intra-operative along the time of the study)
研究者
Ismail Fathy Ahmed Mohammed
M.Sc
Cairo University
