Closure of Implant Emergence Profile
试验速览
- 阶段
- 不适用
- 入组人数
- 16
- 试验地点
- 1
- 主要终点
- Calculation of the volume of the PEI from to T5 min
研究概览
简要总结
In the case of unitary edentulousness, a dental implant is a prosthetic device fixed in the bone which makes it possible to receive a fixed dental prosthesis (crown). Peri-implant soft tissues (gums) play an essential role in the integration of the crown. Indeed, the implant gingival emergence profile provides an aesthetic integration mimicking that of a natural tooth. This implant emergence profile (EIP) is modeled during the surgical and / or prosthetic phases.
The problem comes from the labile character of the EIP (Emergence Implant Profile). If the literature evokes this problem, the instability of the volume of the EIP during the impression phases has never been measured. Moreover, the three-dimensional behavior of the EIP over time (kinetic) during the acquisition phases is not known.
Objective study of the mobility of gingival tissues of the implant emergence profile (IEP), using an intra-oral optical camera, would scientifically measure the labile aspect of the IEP and improve the procedure of registration of peri-implant soft tissues
详细描述
Objective study of the mobility of gingival tissues of the implant emergence profile (IEP), using an intra-oral optical camera, would scientifically measure the labile aspect of the IEP and improve the procedure of registration of peri-implant soft tissues.
The main objective is to study the effect of removal of a healing abutment on the closure of the EIP volume at 5 minutes.
This non-interventional study is a prospectively recruited research of the participants and a cross-sectional measure of the judgment criteria (during a single visit). The study is mono-centric, it will take place in the odontology department of Toulouse Hospital.
The question is to know if the decrease in the volume of the PEI is significant during the preparatory phase of the implant impression where the PEI is no longer supported by the healing screw over a period of 5 minutes.
Optical impressions are designed to record adjacent implant site teeth and peri-implant soft tissue PEI using a Optical Camera. The optical camera works like a camera and does not come into contact with the patient's mucous membranes or teeth. The images obtained are saved in STL format on an anonymized file.
研究设计
- 研究类型
- Observational
- 观察模型
- Other
- 时间视角
- Prospective
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Patient from the Department of Dentistry who has received an implant in the maxillary or mandible, anterior sector or 1st premolar, and presents himself for the prosthetic stages of the implant treatment (realization of the crown of use),
- •Patient affiliated with Social Security,
- •Patient having given no objection to his participation in this study
- •Good written and oral comprehension of French
排除标准
- •Patient who has received an implant intended to receive a removable prosthesis.
- •Patient under court bail, tutelage
结局指标
主要结局
Calculation of the volume of the PEI from to T5 min
时间窗: 5 minutes
Calculation of the volume of the PEI at T0 min from T5 min : They will be named respectively: - Flight T0 min : The reference volume is the volume of the PEI at T0 min, it corresponds to the volume of the healing screw created during the mucosal healing phase and which must be kept for the production of the crown of use. It will be called: Vol T0 min. Hypothesis H0 is that Vol T0 min is fixed over time. If a volume change of 10% is observed, it is assumed that the clinical consequences are real and that the IEP volume will be undersized compared to the reference IEP. This will have aesthetic and functional consequences. The measurement tool of the study is the intraoral scanner.
次要结局
- The volume variation as a percentage of Vol T0.5 min and Vol T2 min(5 minutes)
- The null hypothesis H0 will be a zero variation(2 years)
- Hypothesis H1 will be a percentage of positive and successively larger variation of Vol T30 dry and Vol T2 min.(2 years)
