Timely Acquirement of 12-lead Electrocardiography Using Patchy-type Wireless Device by Emergency Medical Technicians in Ambulance ; A Simulation Study

Samsung Medical Center1 site in 1 country24 target enrollmentStarted: October 25, 2019Last updated:
Conditions
Interventions

Trial Snapshot

Phase
Not Applicable
Status
Completed
Enrollment
24
Locations
1
Primary Endpoint
Time from 12-lead ECG device application starting to sending ECG result to hospital.

Study Overview

Brief Summary

In this study, the investigators compare timely acquirement and effectiveness of 12-lead ECG using patchy-type wireless versus using defibrillator which contain ECG examination function in ambulance.

The purpose of this study is to determine the difference of timely acquirement of 12-lead ECG using two different systems and the difference of efficiency of ECG examination in ambulance between two groups.

The participants in this simulation study were divided randomly into 2 groups :

Group A is performing an ECG examination on mock patient using defibrillator which contained 12-lead ECG checking function. And take a 15 minutes wash out period. After the wash out period, group A subject performing an ECG examination using patchy-type wireless device.

Group B subject is performing an ECG examination on mock patient using patchy-type wireless device first, and take a 15 minutes wash out period. After the wash out period, group B performing an ECG examination using defibrillator which contain 12-lead ECG function.

Both group's ECG examination is performing in the ambulance.

Study Design

Study Type
Interventional
Allocation
Randomized
Intervention Model
Crossover
Primary Purpose
Other
Masking
None

Eligibility Criteria

Ages
19 Years to 65 Years (Adult, Older Adult)
Sex
All
Accepts Healthy Volunteers
Yes

Inclusion Criteria

  • •Who have a certification of Emergency Medical Technician in korea and have a nurse license in korea.
  • •who currently engaged of emergency medical dispatch.

Exclusion Criteria

  • •A subject who did not agree with this study

Arms & Interventions

Group A : defibrillator ECG to patchy-type ECG

Active Comparator

Group A subject will performing ECG examination to a mock patient in the ambulance.

First ECG performance will be using defibrillator which contain 12-lead ECG checking function. And taking a 15 minutes wash out period. Second ECG performance after wash out period, will be using patchy-type wireless device.

when ECG examination performance ended, survey of patchy-type wireless ECG device usability will be collect.

Intervention: defibrillator ECG (Device)

Group B : patchy-type ECG to defibrillator ECG

Experimental

Group B subject will performing ECG examination to a mock patient in the ambulance.

First ECG performance will be using patchy-type wireless device.

And taking a 15 minutes wash out period. Second ECG performance after wash out period, will be using defibrillator which contain 12-lead ECG checking function.

when ECG examination performance ended, survey of patchy-type wireless ECG device usability will be collect.

Intervention: patchy-type wireless ECG (Device)

Outcomes

Primary Outcomes

Time from 12-lead ECG device application starting to sending ECG result to hospital.

Time Frame: through study completion, an average of 2 month

comparison of interval from the start of 12-lead ECG device application to complete of ECG result sending

Secondary Outcomes

  • Usability of patchy-type wireless ECG device.(survey collecting through study completion an average of 2 month)

Investigators

Sponsor Class
Other
Responsible Party
Sponsor