Timely Acquirement of 12-lead Electrocardiography Using Patchy-type Wireless Device by Emergency Medical Technicians in Ambulance ; A Simulation Study
Trial Snapshot
- Phase
- Not Applicable
- Status
- Completed
- Sponsor
- Samsung Medical Center
- Enrollment
- 24
- Locations
- 1
- Primary Endpoint
- Time from 12-lead ECG device application starting to sending ECG result to hospital.
Study Overview
Brief Summary
In this study, the investigators compare timely acquirement and effectiveness of 12-lead ECG using patchy-type wireless versus using defibrillator which contain ECG examination function in ambulance.
The purpose of this study is to determine the difference of timely acquirement of 12-lead ECG using two different systems and the difference of efficiency of ECG examination in ambulance between two groups.
The participants in this simulation study were divided randomly into 2 groups :
Group A is performing an ECG examination on mock patient using defibrillator which contained 12-lead ECG checking function. And take a 15 minutes wash out period. After the wash out period, group A subject performing an ECG examination using patchy-type wireless device.
Group B subject is performing an ECG examination on mock patient using patchy-type wireless device first, and take a 15 minutes wash out period. After the wash out period, group B performing an ECG examination using defibrillator which contain 12-lead ECG function.
Both group's ECG examination is performing in the ambulance.
Study Design
- Study Type
- Interventional
- Allocation
- Randomized
- Intervention Model
- Crossover
- Primary Purpose
- Other
- Masking
- None
Eligibility Criteria
- Ages
- 19 Years to 65 Years (Adult, Older Adult)
- Sex
- All
- Accepts Healthy Volunteers
- Yes
Inclusion Criteria
- •Who have a certification of Emergency Medical Technician in korea and have a nurse license in korea.
- •who currently engaged of emergency medical dispatch.
Exclusion Criteria
- •A subject who did not agree with this study
Arms & Interventions
Group A : defibrillator ECG to patchy-type ECG
Group A subject will performing ECG examination to a mock patient in the ambulance.
First ECG performance will be using defibrillator which contain 12-lead ECG checking function. And taking a 15 minutes wash out period. Second ECG performance after wash out period, will be using patchy-type wireless device.
when ECG examination performance ended, survey of patchy-type wireless ECG device usability will be collect.
Intervention: defibrillator ECG (Device)
Group B : patchy-type ECG to defibrillator ECG
Group B subject will performing ECG examination to a mock patient in the ambulance.
First ECG performance will be using patchy-type wireless device.
And taking a 15 minutes wash out period. Second ECG performance after wash out period, will be using defibrillator which contain 12-lead ECG checking function.
when ECG examination performance ended, survey of patchy-type wireless ECG device usability will be collect.
Intervention: patchy-type wireless ECG (Device)
Outcomes
Primary Outcomes
Time from 12-lead ECG device application starting to sending ECG result to hospital.
Time Frame: through study completion, an average of 2 month
comparison of interval from the start of 12-lead ECG device application to complete of ECG result sending
Secondary Outcomes
- Usability of patchy-type wireless ECG device.(survey collecting through study completion an average of 2 month)