临床试验/NCT02892448
NCT02892448已完成不适用

Cardiac MRI for Metal on Metal Orthopaedic Prostheses

Ottawa Hospital Research Institute2 个研究点 分布在 1 个国家目标入组 35 人开始时间: 2016年9月最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
35
试验地点
2
主要终点
Comprehensive Cardiac Function

研究概览

简要总结

There may be a relationship between heart function and the metal ion levels in patients having undergone total hip replacement. The idea is to use results from a clinical cardiac MRI to assess heart function in a sample of 30 patients whom have undergone either metal-on-metal hip replacement (unilateral or bilateral) or a non-metal on metal total hip replacement to determine whether having undergone a metal on metal hip procedure may be impacting heart function. In addition to the clinically used parameters, the images will also be retrospectively assessed using special software to assess amount of fibrosis and early changes affecting cardiac muscle contraction which may be indicative of impaired heart function. With these values we will compare to known, and previously collected, hip replacement and function data to determine whether there is any differences in how the heart works in those having had a hip replacement relative to a normal population.

详细描述

There has been some recent concern regarding possible systemic health effects resulting from elevated blood cobalt concentrations in patients with cobalt containing hip implants (1). To date there are no blood cobalt criteria to help guide physicians when evaluating an individual hip implant patient's risk of developing systemic health effects because historically there was little or no concern about systemic cobalt toxicity in implant patients. Included within this is heart function, for which investigators see a need to use this novel software to analyze heart function relative to Hip status and Metal Ion levels.

Patients with metal on metal hip prosthesis are subject to local and systemic release of cobalt and chromium ions which may increase the potential for locally aggressive ion-induced local tissue reactions such as pseudotumours, a type of Adverse Reaction to Metal Debris (ARMD) (2). Although there have been reports of local toxicity as well as cases of cobaltism (as seen during outbreak in Quebec of so called 'cobalt beer drinkers' cardiomyopathy) leading to cardiac and ototoxicity, it is unclear if chronic exposure to these ions can lead to impaired cardiac function (cardiotoxicity) in a well-functioning prosthesis.

The majority of the blood cobalt concentrations reported for hip implant patients appear to range from approximately 0.2 to 10 µg/L, and based on our review of the available literature, should not pose an increased risk for the development of systemic health effects.

The concern for systemic health effects is for the small number of patients with cobalt-containing hip implants with markedly elevated blood cobalt concentrations.

Extensive evaluations of these 'cobalt beer drinkers' have found that poor nutrition and underlying disease states caused by severe alcoholism were likely significant contributing factors to heart disease in this particular population. However, there remains a significant concern that cardiac function could be affected in the long term. This is especially relevant as the majority of these implants are put in patients less than 50 years age.

研究设计

研究类型
Interventional
分配方式
Non Randomized
干预模型
Parallel
主要目的
Other
盲法
None

入排标准

性别
All
接受健康志愿者

入选标准

  • Undergoing clinical Cardiac MRI
  • Currently enrolled with either unilateral or bilateral metal-on-metal (MoM) Hip replacement device
  • Willing to sign Informed Consent Form

排除标准

  • Patient does not meet all 'inclusion' criteria

结局指标

主要结局

Comprehensive Cardiac Function

时间窗: One time measure at CMR

Volume measures including: left ventricular end-diastolic volume, left ventricular stroke volume, right ventricular end-diastolic volume, right ventricular end-systolic volume, right ventricular stroke volume

T2* Mapping Time

时间窗: One time measure at CMR

T2\* is a specific sequence in the cardiac MRI and mapping can lead to important indicators of cardiac structure and function.

Cardiac Ejection Fraction

时间窗: Minimum 5 years post-operative

The volumetric fraction of fluid ejected from a chamber with each contraction.

T1 Mapping Time

时间窗: One time measure at CMR

T1 is a specific sequence in the cardiac MRI and mapping can lead to important indicators of cardiac structure and function.

次要结局

  • Cobalt and Chromium Ion Levels(Immediately Prior to cardiac MRI)

研究者

申办方类型
Other
责任方
Sponsor

研究点 (2)

Loading locations...