Skip to main content
Clinical Trials/CTRI/2025/03/082650
CTRI/2025/03/082650
Completed
Phase 3

COMPARISON OF DIGITAL INTEROCCLUSAL RECORD ACCURACY AND OCCLUSAL DISCREPANCY ON TERMINAL ABUTMENT WITH AND WITHOUT PRESERVING VERTICAL STOP AN IN VIVO STUDY

Dr Rupa G1 site in 1 country10 target enrollmentStarted: April 21, 2025Last updated:

Overview

Phase
Phase 3
Status
Completed
Sponsor
Dr Rupa G
Enrollment
10
Locations
1
Primary Endpoint
the accuracy of interocclusal record recorded using intra oral scanner in a terminal abutment

Overview

Brief Summary

Various studies have determined the accuracy and precision of the use of intraoral scanners (IOS) in clinical practice. However studies on accuracy in reproducing the inter-occlusal contacts in the terminal abutments is scarce. When the posterior most tooth is considered as the abutment for the fabrication of a fixed prosthesis, which is otherwise known as terminal abutment. There are challenges encountered in accurate transfer of the inter occlusal record to the articulator, as there is loss in the tripod configuration to articulate the cast due to improper seating of the condyle and loss of proprioception leading to eccentric contacts. By preserving the distal cusp as a vertical stop in a full coverage preparation, the tripod relation can be achieved.

The intention of this clinical study is to assess the occlusal discrepancy and accuracy of intraoral scanners in recording the inter-occlusal records on a terminal abutment by preserving the centric stop and compare them with the conventional method.

Study Design

Study Type
Interventional
Allocation
Na
Masking
None

Eligibility Criteria

Ages
25.00 Year(s) to 45.00 Year(s) (—)
Sex
All

Inclusion Criteria

  • PATIENTS WITH ONE OR TWO MISSING TEETH IN MANDIBULAR POSTERIOR REGION WITH ONE TOOTH PRESENT POSTERIOR TO MISSING REGION.

Exclusion Criteria

  • Patients with a history of TMJ dysfunction or myofascial pain dysfunction syndrome patients with limitation of mandibular movement.

Outcomes

Primary Outcomes

the accuracy of interocclusal record recorded using intra oral scanner in a terminal abutment

Time Frame: The outcome will be assessed at baseline after prosthesis

Secondary Outcomes

  • the accuracy of occlusion obtained preserving the vertical stop(The occlusion will be assessed at baseline)