Localizing the Epileptogenic Zone With High Resolution Electroencephalography
- Conditions
- Partial Epilepsy
- Interventions
- Device: High Resolution EEGDevice: Stereo-electroencephalography
- Registration Number
- NCT01090934
- Lead Sponsor
- Central Hospital, Nancy, France
- Brief Summary
Multicenter prospective study comparing the diagnosis value of high-resolution EEG and depth-EEG to localize the epileptogenic zone in drug resistant partial epilepsies.
- Detailed Description
Not available
Recruitment & Eligibility
- Status
- COMPLETED
- Sex
- All
- Target Recruitment
- 115
- medically intractable patial epilepsy confirmed by video-EEG recordings of epileptic seizures.
- Depth EEG (Stereo-EEG) required to delineate the epileptogenic zone and define the surgical procedure.
- full informed consent of the patient (or of his/ her legal representative)
- 15 year or older patient
-
contraindication to cortectomy
-
contraindication to depth-EEG
-
indication of epilepsy surgery without depth-EEG monitoring
-
high grade glioma, arterio-veinous malformations
- pregnancy
- history of severe cardio-vascular event (coronaropathy, stroke)
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- SINGLE_GROUP
- Arm && Interventions
Group Intervention Description high resolution EEG High Resolution EEG - Stereo Electroencephalography Stereo-electroencephalography -
- Primary Outcome Measures
Name Time Method Sensitivity and specificity of electrical source localization of inter-ictal and ictal discharges using high-Resolution EEG for localizing the epileptogenic zone (the stereo-electroencephalography will be the reference method) 3 years results of electrical sources localization of inter-ictal and ictal discharges are compared to the epileptogenic zone defined by SEEG
- Secondary Outcome Measures
Name Time Method inter-observer reliability of electrical source localization of inter-ictal and ictal discharges for localizing the epileptogenic zone. 3 years sources localization of inter-ictal and ictal discharges will be interpreted by two independant epileptologists, blinded to the results of stereo-EEG.
sensitivity and specificity of high resolution EEG and electrical source imaging for surgical decision 3 years decision of surgery and the limits of the cortectomy established with electrical source imaging will be compared to the decision of surgery and the limits of the cortectomy established with Stereo-electroencephalography.
Trial Locations
- Locations (2)
Central Hospital
🇫🇷Nancy, France
University Hospital of Marseille
🇫🇷Marseille, France